Adaptec 412R User Guide - Page 134

B-2, see one LUN, instead of both.

Page 134 highlights

Figure B-2 Controller 2 Failed B-4 Host 1 FC HBA See's LUN 1 & LUN 2 FC HBA See's LUN 1 & LUN 2 HOST I/O P1 P2 RAID Controller HUB FC1 LUN 1 Disk Active CH1 HUB FC2 LUN 2 Active Disk CH2 See's LUN 1 & LUN 2 Host 2 P4 FC HBA P3 Disk CH0 Disk CH3 Controller 1 FC HBA See's LUN 1 & LUN 2 Host I/O Connectors RAID Controller FC1 LUN 2 Active Disk T CH1 FC2 LUN 2 Active Disk CH2 T Disk T CH0 Disk CH3 Controller 2 T FAILED Drives 7 - 12 Drives 1 - 6 Disk I/O Connectors T SEP T SEP SAF-TE Disk I/O Card T T I/O Card T= Location of internal termination CH 0 CH 3 CH 1 CH 2 Figure B-2 illustrates the conditions when Controller 2 fails. Note that both hosts can still see Controller 1's LUNs (LUN 1) and Controller 2's LUNS (LUN 2). However, each host HBA can only see one LUN, instead of both. DuraStor 412R/6320SS/7320SS Installation and User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210

B-4
DuraStor 412R/6320SS/7320SS Installation and User’s Guide
Figure B-2
illustrates the conditions when Controller 2 fails. Note
that both hosts can still see Controller 1’s LUNs (LUN 1) and
Controller 2’s LUNS (LUN 2). However, each host HBA can only
see one LUN, instead of both.
Figure B-2
Controller 2 Failed
Host 2
FC HBA
FC HBA
Host 1
FC HBA
FC HBA
See's LUN 1 & LUN 2
See's LUN 1 & LUN 2
See's LUN 1 & LUN 2
See's LUN 1 & LUN 2
LUN 2
LUN 1
Active
Active
RAID Controller
SEP
T= Location of internal termination
T
T
Controller 1
SAF-TE Disk I/O Card
Disk
CH1
Drives 7 - 12
Drives 1 - 6
Disk
CH2
Disk
CH0
Disk
CH3
FC2
FC1
P1
P2
CH 1
CH 2
P3
P4
HOST I/O
RAID Controller
Controller 2
FAILED
Disk
CH1
Disk
CH2
Disk
CH0
Disk
CH3
FC2
FC1
T
T
T
T
SEP
T
T
I/O Card
CH 0
CH 3
HUB
HUB
Host I/O
Connectors
Disk I/O
Connectors