Adaptec 412R User Guide - Page 150

RAID – 36-Drive Configuration, Reinstall the SAF-TE disk I/O card in each enclosure. See

Page 150 highlights

DuraStor 412R/6320SS/7320SS Installation and User's Guide RAID - 36-Drive Configuration Only the DuraStor 6320SS in the stand-alone single-port mode can be setup in this configuration. It provides up to a 36 disk drive storage solution (12 per channel). This is due to one of the host I/O ports (CH 3) is used as a drive channel to provide the additional connectivity for the second DuraStor 412R drive enclosure. 1 Remove the SAF-TE disk I/O card installed in both enclosures. See Replacing an I/O Card on page 5-21 for instructions. 2 Locate the switches on each card and set them as shown in Figure C-6. The switch settings assign specific SCSI IDs to the drive slots as indicated, and reserve IDs 6 and 7 for the RAID controllers, and IDs 8 or 15 for the SAF-TE processors. SAF-TE ID = 8/8 RAID Controllers = 6 & 7 Switch Settings A A RS S BDR 0 1D0 1DLM UP (1) 1 2 3 4 5 6 7 8 DOWN (0) Slot 1 ID 1 Slot 2 ID 3 Slot 3 ID 5 Dual-Bus Mode Slot 4 ID 2 Slot 7 ID 1 Slot 5 ID 4 Slot 8 ID 3 Slot 6 ID 0 Slot 9 ID 5 Slot 10 ID 2 Slot 11 ID 4 Slot 12 ID 0 Drive IDs of the Drive Slots (Drive Channel Side) Figure C-9 Switch Setting - Primary RAID Enclosure 3 Reinstall the SAF-TE disk I/O card in each enclosure. See Replacing an I/O Card on page 5-21 for instructions. 4 Remove the SAF-TE disk I/O card installed in the daisy-chain enclosure. See Replacing an I/O Card on page 5-21 for instructions. The first daisy-chain enclosure will be configured to dual-bus mode. This provides the drive channel expansion from the C-8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210

C-8
DuraStor 412R/6320SS/7320SS Installation and User’s Guide
RAID – 36-Drive Configuration
Only the DuraStor 6320SS in the stand-alone single-port mode can
be setup in this configuration. It provides up to a 36 disk drive
storage solution (12 per channel). This is due to one of the host I/O
ports (CH 3) is used as a drive channel to provide the additional
connectivity for the second DuraStor 412R drive enclosure.
1
Remove the SAF-TE disk I/O card installed in both enclosures.
See
Replacing an I/O Card
on page 5-21
for instructions.
2
Locate the switches on each card and set them as shown in
Figure C-6
.
The switch settings assign specific SCSI IDs to the drive slots as
indicated, and reserve IDs 6 and 7 for the RAID controllers, and
IDs 8 or 15 for the SAF-TE processors.
Figure C-9
Switch Setting
Primary RAID Enclosure
3
Reinstall the SAF-TE disk I/O card in each enclosure. See
Replacing an I/O Card
on page 5-21
for instructions.
4
Remove the SAF-TE disk I/O card installed in the daisy-chain
enclosure. See
Replacing an I/O Card
on page 5-21
for
instructions.
The first daisy-chain enclosure will be configured to dual-bus
mode. This provides the drive channel expansion from the
Switch Settings
ID 1
ID 1
Slot 1
Slot 7
Slot 4
Slot 10
Slot 2
Slot 8
Slot 5
Slot 11
Slot 3
Slot 9
Slot 6
Slot 12
ID 3
ID 3
ID 5
ID 5
ID 2
ID 2
ID 4
ID 4
ID 0
ID 0
UP (1)
DOWN (0)
Drive IDs of the Drive Slots (Drive Channel Side)
SAF-TE ID = 8/8
RAID Controllers = 6 & 7
Dual-Bus Mode
A
0
1
A
1
2
R
D
3
S
0
4
S
1
5
B
D
6
D
L
7
R
M
8