Adaptec 412R User Guide - Page 136
LUN 1 and Controller 2's LUNs LUN 2. However, each host, B-4
![]() |
UPC - 760884139691
View all Adaptec 412R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 136 highlights
Figure B-4 Controller 2 Failed B-6 Host 1 FC HBA See's LUN 1 See's LUN 2 FC HBA Switch 1 HOST I/O P1 P2 Host 2 FC HBA See's LUN 1 FC HBA See's LUN 2 Switch 2 P4 P3 Host I/O Connectors RAID Controller FC1 LUN 1 Disk Active CH1 FC2 LUN 2 Active Disk CH2 Disk CH0 Disk CH3 Controller 1 RAID Controller FC1 LUN 2 In-Active FC2 LUN 2 In-Active Disk T CH1 Disk CH2 T Disk T CH0 Disk CH3 Controller 2 T FAILED Drives 7 - 12 Drives 1 - 6 T= Location of internal termination Disk I/O Connectors T SEP T SEP SAF-TE Disk I/O T T Disk I/O CH 0 CH 3 CH 1 CH 2 In Figure B-4, two hosts are connected via two independent switches. Note that both hosts can still see Controller 1's LUNs (LUN 1) and Controller 2's LUNs (LUN 2). However, each host HBA can only see one LUN, instead of both. DuraStor 412R/6320SS/7320SS Installation and User's Guide