Adaptec 412R User Guide - Page 63
Replacing a “Killed” Controller, Active-Active Mode only.
UPC - 760884139691
View all Adaptec 412R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
Understanding and Maintaining Components 6 Using one of the storage management tools (see page 1-5),verify that the replacement RAID controller has the correct firmware. Note: Active-active and active-passive dual-controllers require the same version of firmware on both controllers. 7 (Active-Active Mode only.) Using one of the storage management tools (see page 1-5), relinquish the partner controller. Replacing a "Killed" Controller If one controller detects that the other has a problem, it will kill it, and output an appropriate event. If it is determined that the controller has a permanent failure, then it must be replaced. Whether in active-active or active-passive mode, simply replace the defective controller and ensure that the firmware on it is at the same level as the surviving controller. If required, upload the correct firmware. Also, ensure that the new controller is set to the same operating mode. The new controller completes its boot cycle and goes online automatically. 5-5