Adaptec 412R User Guide - Page 152

Replacing an I/O Card, Basic Connections, DuraStor 6320SS, Advanced Cabling

Page 152 highlights

DuraStor 412R/6320SS/7320SS Installation and User's Guide 9 Configure the jumper settings on this second daisy-chain enclosure SAF-TE disk I/O card. Locate and add (installed on both pins) the two jumpers at JP7 and JP8. The default position of the jumpers are offset. 10 Reinstall the SAF-TE disk I/O card in each enclosure. See Replacing an I/O Card on page 5-21 for instructions. 11 Connect the SCSI data cables as shown in Figure C-8. SCSI Data Cable SCSI Data Cable Power Power Supply Supply Cooling Fans SAFTE Disk I/O Chl 1 Chl 2 SCSI Disk I/O Chl 0 Chl 3 Host I/O P1 P2 P4 P3 Ctlr 1 SAF-TE Ctlr 2 RAID Controller Primary enclosure Power Power Supply Supply Cooling Fans Power Power Supply Supply Cooling Fans SAFTE Disk I/O Chl 1 Chl 2 Ctlr 1 SAF-TE Ctlr 2 SAFTE Disk I/O Chl 1 Chl 2 Ctlr 1 SAF-TE Ctlr 2 First daisy-chain enclosure SCSI Data Cable Single Bus Module Second daisy chain enclosure Figure C-12 Enclosure Cabling Diagram 12 Connect a SCSI data cable from the host system(s) HBA(s) to the host I/O card as indicated in Basic Connections - DuraStor 6320SS on page 2-15 or Advanced Cabling - DuraStor 6320SS on page C-21. The configuration is complete. Refer to the Storage Manager Pro User's Guide or the Disk Array Administrator User's Guide for instructions on how to set up and configure disk arrays. C-10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210

C-10
DuraStor 412R/6320SS/7320SS Installation and User’s Guide
9
Configure the jumper settings on this second daisy-chain
enclosure SAF-TE disk I/O card.
Locate and add (installed on both pins) the two jumpers at JP7
and JP8. The default position of the jumpers are offset.
10
Reinstall the SAF-TE disk I/O card in each enclosure. See
Replacing an I/O Card
on page 5-21
for instructions.
11
Connect the SCSI data cables as shown in
Figure C-8
.
Figure C-12
Enclosure Cabling Diagram
12
Connect a SCSI data cable from the host system(s) HBA(s) to the
host I/O card as indicated in
Basic Connections –
DuraStor 6320SS
on page 2-15
or
Advanced Cabling –
DuraStor 6320SS
on page C-21
.
The configuration is complete. Refer to the
Storage Manager Pro
User’s Guide
or the
Disk Array Administrator User’s Guide
for
instructions on how to set up and configure disk arrays.
SAFTE Disk I/O
SCSI Data Cable
SCSI Data Cable
SCSI Data Cable
Chl 1
Ctlr 1
Ctlr 2
SAF-TE
Chl 2
Power
Supply
Power
Supply
Cooling
Fans
SAFTE Disk I/O
SAFTE Disk I/O
Chl 1
Ctlr 1
Ctlr 2
SAF-TE
Chl 2
Power
Supply
Power
Supply
Cooling
Fans
Chl 1
Ctlr 1
Ctlr 2
SAF-TE
Chl 2
Chl 0
Chl 3
SCSI Disk I/O
RAID Controller
Single Bus
Module
Power
Supply
Power
Supply
Cooling
Fans
Host I/O
P1
Second daisy chain
enclosure
First daisy-chain
enclosure
Primary
enclosure