Adaptec 412R User Guide - Page 151

SAF-TE disk I/O card., Advanced Configurations and Cabling

Page 151 highlights

Advanced Configurations and Cabling primary enclosures' disk I/O channels. Set the switches as shown in Figure C-7. SAF-TE ID = 15/15 RAID Controllers = 6 & 7 Switch Settings A A RS S BDR 0 1D0 1DLM UP (1) 1 2 3 4 5 6 7 8 DOWN (0) Slot 1 ID 9 Slot 2 ID 11 Slot 3 ID 13 Dual-Bus Mode Slot 4 ID 10 Slot 7 ID 9 Slot 5 ID 12 Slot 8 ID 11 Slot 6 ID 14 Slot 9 ID 13 Slot 10 ID 10 Slot 11 ID 12 Slot 12 ID 14 Drive IDs of the Drive Slots (Drive Channel Side) Figure C-10 Switch Setting - Dual-Bus Daisy-Chain Enclosure 5 Configure the jumper settings on this first daisy-chain enclosure SAF-TE disk I/O card. Locate and add (installed on both pins) the jumpers at JP7 and JP8. See Figure 5-14 on page 5-17 for help locating the jumpers. The default position of the jumpers are offset (installed on one pin only). This ensures that the automatic termination feature functions properly. 6 Reinstall the SAF-TE disk I/O card in each enclosure. See Replacing an I/O Card on page 5-21 for instructions. 7 Remove the SAF-TE disk I/O card installed in the second daisychain enclosure. See Replacing an I/O Card on page 5-21 for instructions. 8 Locate the switches on the card and set them as shown in Figure C-11. SAF-TE ID = 15 RAID Controllers = 6 & 7 Switch Settings A A RS S BDR 0 1D0 1DLM UP (1) 1 2 3 4 5 6 7 8 DOWN (0) Slot 1 ID 1 Slot 2 ID 3 Slot 3 ID 5 Single-Bus Mode Slot 4 ID 2 Slot 7 ID 9 Slot 5 ID 4 Slot 8 ID 1 1 Slot 6 ID 0 Slot 9 ID 1 3 Slot 10 ID 1 0 Slot 11 ID 1 2 Slot 12 ID 1 4 Drive IDs of the Drive Slots (Drive Channel Side) Figure C-11 Switch Setting - Single-Bus Daisy-Chain Enclosure C-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210

C-9
Advanced Configurations and Cabling
primary enclosures’ disk I/O channels. Set the switches as
shown in
Figure C-7
.
Figure C-10
Switch Setting
Dual-Bus Daisy-Chain Enclosure
5
Configure the jumper settings on this first daisy-chain enclosure
SAF-TE disk I/O card.
Locate and add (installed on both pins) the jumpers at JP7 and
JP8. See
Figure 5-14 on page 5-17
for help locating the jumpers.
The default position of the jumpers are offset (installed on one
pin only).
This ensures that the automatic termination feature functions
properly.
6
Reinstall the SAF-TE disk I/O card in each enclosure. See
Replacing an I/O Card
on page 5-21
for instructions.
7
Remove the SAF-TE disk I/O card installed in the second daisy-
chain enclosure. See
Replacing an I/O Card
on page 5-21
for
instructions.
8
Locate the switches on the card and set them as shown in
Figure C-11
.
Figure C-11
Switch Setting
Single-Bus Daisy-Chain Enclosure
Switch Settings
ID 9
ID 9
Slot 1
Slot 7
Slot 4
Slot 10
Slot 2
Slot 8
Slot 5
Slot 11
Slot 3
Slot 9
Slot 6
Slot 12
ID 11
ID 11
ID 13
ID 13
ID 10
ID 10
ID 12
ID 12
ID 14
ID 14
UP (1)
DOWN (0)
Drive IDs of the Drive Slots (Drive Channel Side)
SAF-TE ID = 15/15
RAID Controllers = 6 & 7
Dual-Bus Mode
A
0
1
A
1
2
R
D
3
S
0
4
S
1
5
B
D
6
D
L
7
R
M
8
Switch Settings
ID 1
ID 9
Slot 1
Slot 7
Slot 4
Slot 10
Slot 2
Slot 8
Slot 5
Slot 11
Slot 3
Slot 9
Slot 6
Slot 12
ID 3
ID 11
ID 5
ID 13
ID 2
ID 10
ID 4
ID 12
ID 0
ID 14
UP (1)
DOWN (0)
Drive IDs of the Drive Slots (Drive Channel Side)
SAF-TE ID = 15
RAID Controllers = 6 & 7
Single-Bus Mode
A
0
1
A
1
2
R
D
3
S
0
4
S
1
5
B
D
6
D
L
7
R
M
8