Adaptec 412R User Guide - Page 157

Replacing an I/O Card, Installing the Single Bus Module and, Cover Plate

Page 157 highlights

Advanced Configurations and Cabling 7 Remove the SAF-TE disk I/O card installed in the second daisychain enclosure. See Replacing an I/O Card on page 5-21 for instructions. The second daisy-chain enclosure is configured to single-bus mode. It provides the drive channel expansion from the primary enclosures' I/O card Channel 0. Set the switches as shown in Figure C-17. SAF-TE ID = 15 RAID Controllers = 6 & 7 Switch Settings A A RS S BDR 0 1D0 1DLM UP (1) 1 2 3 4 5 6 7 8 DOWN (0) Slot 1 ID 1 Slot 2 ID 3 Slot 3 ID 5 Single-Bus Mode Slot 4 ID 2 Slot 7 ID 9 Slot 5 ID 4 Slot 8 ID 1 1 Slot 6 ID 0 Slot 9 ID 1 3 Slot 10 ID 1 0 Slot 11 ID 1 2 Slot 12 ID 1 4 Drive IDs of the Drive Slots (Drive Channel Side) Figure C-17 Switch Setting - Single-Bus Daisy-Chain Enclosure 8 (Second Daisy-chain Enclosure) Change the jumper settings on the SAF-TE disk I/O card JP7 and JP8 as described. Locate and add the two jumpers (JP7 and JP8). See Figure 5-14 on page 5-17 for help locating the jumpers. Add a jumper (installed on both pins) to JP8 for Channel 1 and JP7 for Channel 2. This will ensure that the automatic termination feature functions properly. 9 Reinstall the SAF-TE disk I/O card into the second daisy-chain enclosure. See Replacing an I/O Card on page 5-21 for instructions. 10 (Second Daisy-chain Enclosure) Install the Single-Bus Module in the Controller 1 slot. See Installing the Single Bus Module and Cover Plate on page 5-9 for instructions. 11 Connect the SCSI data cables from the DuraStor 7320SS to the two daisy-chain enclosures as shown in Figure C-15 on page C-13. C-15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210

C-15
Advanced Configurations and Cabling
7
Remove the SAF-TE disk I/O card installed in the second daisy-
chain enclosure. See
Replacing an I/O Card
on page 5-21
for
instructions.
The second daisy-chain enclosure is configured to single-bus
mode. It provides the drive channel expansion from the
primary enclosures’ I/O card Channel 0. Set the switches as
shown in
Figure C-17
.
Figure C-17
Switch Setting
–
Single-Bus Daisy-Chain Enclosure
8
(Second Daisy-chain Enclosure)
Change the jumper settings on the
SAF-TE disk I/O card JP7 and JP8 as described.
Locate and add the two jumpers (JP7 and JP8). See
Figure 5-14
on page 5-17
for help locating the jumpers. Add a jumper
(installed on both pins) to JP8 for Channel 1 and JP7 for
Channel 2.
This will ensure that the automatic termination feature
functions properly.
9
Reinstall the SAF-TE disk I/O card into the second daisy-chain
enclosure. See
Replacing an I/O Card
on page 5-21
for
instructions.
10
(Second Daisy-chain Enclosure)
Install the Single-Bus Module in
the Controller 1 slot. See
Installing the Single Bus Module and
Cover Plate
on page 5-9
for instructions.
11
Connect the SCSI data cables from the DuraStor 7320SS to the
two daisy-chain enclosures as shown in
Figure C-15 on
page C-13
.
Switch Settings
ID 1
ID 9
Slot 1
Slot 7
Slot 4
Slot 10
Slot 2
Slot 8
Slot 5
Slot 11
Slot 3
Slot 9
Slot 6
Slot 12
ID 3
ID 11
ID 5
ID 13
ID 2
ID 10
ID 4
ID 12
ID 0
ID 14
UP (1)
DOWN (0)
Drive IDs of the Drive Slots (Drive Channel Side)
SAF-TE ID = 15
RAID Controllers = 6 & 7
Single-Bus Mode
A
0
1
A
1
2
R
D
3
S
0
4
S
1
5
B
D
6
D
L
7
R
M
8