Adaptec 412R User Guide - Page 156

First Daisy-chain Enclosure, Locate and add the two jumpers JP7 and JP8. See

Page 156 highlights

DuraStor 412R/6320SS/7320SS Installation and User's Guide The switch settings assign specific SCSI IDs to the drive slots, as shown in Figure C-13 on page C-11, and reserve IDs 6 and 7 for the RAID Controller(s), and IDs 8 or 15 for the SAF-TE processors. 3 Reinstall the SAF-TE disk I/O card in each enclosure. See Replacing an I/O Card on page 5-21 for instructions. 4 Remove the SAF-TE disk I/O card installed in the first daisychain enclosure. See Replacing an I/O Card on page 5-21 for instructions. The first daisy-chain enclosure is configured to dual-bus mode. It provides the drive channel expansion from the primary enclosures' disk I/O channels. Set the switches as shown in Figure C-16. SAF-TE ID = 15/15 RAID Controllers = 6 & 7 Switch Settings A A RS S BDR 0 1D0 1DLM UP (1) 1 2 3 4 5 6 7 8 DOWN (0) Slot 1 ID 9 Slot 2 ID 11 Slot 3 ID 13 Dual-Bus Mode Slot 4 ID 10 Slot 7 ID 9 Slot 5 ID 12 Slot 8 ID 11 Slot 6 ID 14 Slot 9 ID 13 Slot 10 ID 10 Slot 11 ID 12 Slot 12 ID 14 Drive IDs of the Drive Slots (Drive Channel Side) Figure C-16 Switch Setting - Dual-Bus Daisy-Chain Enclosure 5 (First Daisy-chain Enclosure) Change the jumper settings on the SAF-TE disk I/O card JP7 and JP8 as described. Locate and add the two jumpers (JP7 and JP8). See Figure 5-14 on page 5-17 for help locating the jumpers. Add a jumper (installed on both pins) to JP8 for Channel 1 and JP7 for Channel 2. This ensures that the automatic termination feature functions properly. 6 Reinstall the SAF-TE disk I/O card into the daisy-chain enclosure. See Replacing an I/O Card on page 5-21 for instructions. C-14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210

C-14
DuraStor 412R/6320SS/7320SS Installation and User’s Guide
The switch settings assign specific SCSI IDs to the drive slots, as
shown in
Figure C-13 on page C-11
, and reserve IDs 6 and 7 for
the RAID Controller(s), and IDs 8 or 15 for the SAF-TE
processors.
3
Reinstall the SAF-TE disk I/O card in each enclosure. See
Replacing an I/O Card
on page 5-21
for instructions.
4
Remove the SAF-TE disk I/O card installed in the first daisy-
chain enclosure. See
Replacing an I/O Card
on page 5-21
for
instructions.
The first daisy-chain enclosure is configured to dual-bus mode.
It provides the drive channel expansion from the primary
enclosures’ disk I/O channels. Set the switches as shown in
Figure C-16
.
Figure C-16
Switch Setting
Dual-Bus Daisy-Chain Enclosure
5
(First Daisy-chain Enclosure
) Change the jumper settings on the
SAF-TE disk I/O card JP7 and JP8 as described.
Locate and add the two jumpers (JP7 and JP8). See
Figure 5-14
on page 5-17
for help locating the jumpers. Add a jumper
(installed on both pins) to JP8 for Channel 1 and JP7 for
Channel 2.
This ensures that the automatic termination feature functions
properly.
6
Reinstall the SAF-TE disk I/O card into the daisy-chain
enclosure. See
Replacing an I/O Card
on page 5-21
for
instructions.
Switch Settings
ID 9
ID 9
Slot 1
Slot 7
Slot 4
Slot 10
Slot 2
Slot 8
Slot 5
Slot 11
Slot 3
Slot 9
Slot 6
Slot 12
ID 11
ID 11
ID 13
ID 13
ID 10
ID 10
ID 12
ID 12
ID 14
ID 14
UP (1)
DOWN (0)
Drive IDs of the Drive Slots (Drive Channel Side)
SAF-TE ID = 15/15
RAID Controllers = 6 & 7
Dual-Bus Mode
A
0
1
A
1
2
R
D
3
S
0
4
S
1
5
B
D
6
D
L
7
R
M
8