Brother International BAS-375E Instruction Manual - English - Page 30
Using the emergency stop switch
View all Brother International BAS-375E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Chapter 5 OPERATING PROCEDURE 4. Using the emergency stop switch Press the emergency stop switch 1 to immediately stop the sewing machine during actual sewing or when in the test mode. Note There will be no response when the start switch or work clamp lift switch is depressed or pressed when the emergency stop switch q is pushed (the alarm is q sounding). Reset 1. If the EMERGENCY STOP switch q is "turn lock type", turn the EMERGENCY STOP switch q clockwise and w then pull it forward to release it. 2. Press the reset switch w . (The alarm will stop sounding.) 3. If you do not wish to resume sewing, press the EMERGENCY STOP switch q once more and then press the reset switch w so that the program No. on the operation panel flashes. The sewing machine will then be ready for the next sewing operation. If a problem occurs If an abnormal load is applied or a problem occurs , the emergency stop function is automatically activated, all operations stop, and the alarm sounds. If the alarm is sounding intermittently, correct the problem and press the reset switch w to cancel the emergency stop mode. If emergency stop function is not canceled even when EMERGENCY STOP switch is pressed Turn the power off, eliminate the cause of the problem, and then turn the power back on. BAS-364E, 366E, 370E, 375E 24