Brother International BAS-375E Instruction Manual - English - Page 59
Changing Special Functions And Using The Memory Switches, Memory Switches [00] - [0f]
View all Brother International BAS-375E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
Chapter 11 CHANGING SPECIAL FUNCTIONS AND USING THE MEMORY SWITCHES I Memory switches [00] - [0F] SW. No. memo-00 memo-01 memo-02 memo-03 memo-04 memo-05 memo-06 memo-07 memo-08 memo-09 memo-0A memo-0b memo-0c memo-0d memo-0E memo-0F When "on" Feed plate moves in the order X ¡ Y when moving to the home position, and moves in the order Y ¡ X when moving to the sewing start position. Feed plate moves in the order Y ¡ X when moving to the home position, and moves in the order X ¡ Y when moving to the sewing start position. Feed plate moves in the order forward X ¡ Y when moving to the home position, and moves in the order forward X ¡Y when moving to the sewing start position. Eject device operates. If DIP switch A-7 is also ON, eject is on standby so that sewing starts automatically. - Set to "on" when using the 2-step tension device. - I Memory switches [10] - [1F] SW. No. memo-10 memo-11 memo-12 memo-13 memo-14 memo-15 memo-16 memo-17 memo-18 memo-19 memo-1A memo-1b memo-1c memo-1d memo-1E memo-1F When "on" - Lower thread counter and production counter are updated each time thread is trimmed. Upper thread presser operates. Presser foot controller operates at 0.5 - mm intervals. Needle up errors are not detected. - Bottom plunger operates. Jig recognition device operates. - Lower thread counter is decremented at the sewing start. - BAS-364E, 366E, 370E, 375E 53