Cisco ESR10008 Hardware Installation Guide - Page 143

Technical Specifications

Page 143 highlights

A A P P E N D I X Technical Specifications Table A-1 lists the specifications for the Cisco 10008 router. Table A-1 Cisco 10008 Router System Specifications Description Physical specifications Temperature range Relative humidity Operating altitude Airflow Specifications • Weight: 130 lb (59.02 kg) fully configured chassis • Height: 21.75 in. (55.2 cm) • Width: 17.5 in. (44.4 cm) • Depth: 12.0 in. (30.4 cm) • Chassis depth with front cover: 13.75 in. (34.9 cm) • Mounting: 19 in. or 23 in. rack mountable (front or mid), 3 units per 7 ft rack • Operating: 41 degrees F to 104 degrees F (5 degrees C to 40 degrees C) Short-term operating temperature is limited to 131 degrees F (55 degrees C) in compliance with Bellcore GR-63 • Storage: −40 degrees F to 158 degrees F (−40 degrees C to 70 degrees C) • Operating-nominal: 5 percent to 85 percent • Operating-short term: 5 percent to 90 percent • Storage: 5 percent to 95 percent −197 ft to 13,123 ft (-60 m to 4000 m) 150 cfm1 through the system blower module 200 cfm through the system blower module if the exhaust temperature exceeds 45 degrees C OL-0659-13 Cisco 10008 Router Hardware Installation Guide A-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172

A-1
Cisco 10008 Router Hardware Installation Guide
OL-0659-13
APPENDIX
A
Technical Specifications
Table A-1 lists the specifications for the Cisco 10008 router.
Table A-1
Cisco 10008 Router System Specifications
Description
Specifications
Physical specifications
Weight: 130 lb (59.02 kg) fully configured chassis
Height: 21.75 in. (55.2 cm)
Width: 17.5 in. (44.4 cm)
Depth: 12.0 in. (30.4 cm)
Chassis depth with front cover: 13.75 in. (34.9 cm)
Mounting: 19 in. or 23 in. rack mountable (front or mid),
3 units per 7 ft rack
Temperature range
Operating: 41 degrees F to 104 degrees
F (5 degrees
C to 40
degrees
C)
Short-term operating temperature is limited to 131 degrees
F
(55
degrees C) in compliance with Bellcore GR-63
Storage:
40
degrees F
to 158
degrees F (
40
degrees C to
70 degrees C)
Relative humidity
Operating—nominal: 5 percent to 85 percent
Operating—short term: 5 percent to 90 percent
Storage: 5 percent to 95 percent
Operating altitude
−197
ft to 13,123 ft (–60 m to 4000 m)
Airflow
150 cfm
1
through the system blower module
200 cfm through the system blower module if the exhaust temperature
exceeds 45
degrees C