Cisco ESR10008 Hardware Installation Guide - Page 60

Recommended Tools and Supplies

Page 60 highlights

Connecting DC Power to the Cisco 10008 Router Chapter 3 Installing the Cisco 10008 Router Recommended Tools and Supplies Table 3-2 lists the tools and supplies that you need to connect the Cisco 10008 router to DC power sources. Table 3-2 Tools and Supplies Quantity 1 1 2 or 4 (length varies) 2 Description Comments Flat-blade screwdriver - Wire stripping tool - 10 AWG (minimum) wire Cables must reach from the Cisco 10008 router to the DC power source. cables • Two cables are needed for a single DC power source. • Four cables are needed for two DC power sources. Tie wraps • The end of the cable intended to be connected to the chassis needs to have insulation stripped back not more than 0.4 in. (10 mm). Use the following procedure to connect the chassis to a DC power source: Figure 3-16 Setting DC PEM Switches to the Off Position POWER FAULT MISWIRE POWER FAULT MISWIRE LOOP ALARM CARRIER RX TX LINK FANS OK FAFILAUNRE FMAFUILALUNTRI-E WrbseyemhsdteoeonvmnahelsoaihtnnCusduwtAdnarUodepwTeppnIrliaOntcwwgNeioltmlhmoiescnincftauumntre.utsrsaotyr, FAIL FAIL FAIL FAIL 1 C1I0S0C0O0 2 C1I0S0C0O0 3 C1I0S0C0O0 4 CC161I0CS00T0C003O00 FAIL LOOP CARALRAIERRM LOOP CARALRAIERRM 0 PO0RT0 CA ALARLMOOP 1 PO1RT1 2 PO2RT2 3 PO3RT3 4 PO4RT4 5 PO5RT5 0A PROCESSOR ONLY0B CISCO 10000 CISCO 10000 CONSOLE AUX ELAICTNHTKIEVRITNYET CONSOLE AUX ELAICTNHTKIEVRITNYET 5 CC161I0CS00T0C003O00 FAIL 6 CC161I0CS00T0C003O00 FAIL 7 CC161I0CS00T0C003O00 FAIL LOOP CARALRAIERRM LOOP CARALRAIERRM LOOP CARALRAIERRM PO0RT0 CA ALARLMOOP PO0RT0 CA ALARLMOOP PO0RT0 CA ALARLMOOP ACTIVITY LINK ACTIVITY LINK ALARMS ALARMS PO1RT1 PO2RT2 PO1RT1 PO2RT2 PO1RT1 PO2RT2 CRITICMAALJORMINOR ACO PO3RT3 PO3RT3 PO3RT3 PO4RT4 PO4RT4 PO4RT4 PO5RT5 PO5RT5 PO5RT5 RX TX CARRIER CRITICMAALJORMINOR ACO FAIL FAIL FAIL FAIL 8 C1I0S0C0O0 SLOT 0 STATUFSAIL BITS SLOT 0 STATUFSAIL BITS CH OC-12-DSO SM-IR GIGABIT ETHERNET 6XCT3-DS0 6XCT3-DS0 6XCT3-DS0 PERFORMANCE ROUTING ENGINE P/N ESR-PRE3 PERFORMANCE ROUTING ENGINE P/N ESR-PRE3 6XCT3-DS0 6XCT3-DS0 POWER FAULT MISWIRE PROCESSOR ONLY OC-12/STM-4 POS SM-IR 30019 Step 1 Set the DC PEM switch (or switches) to the Off position (Figure 3-16). Warning This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations. Statement 1045 3-18 Cisco 10008 Router Hardware Installation Guide OL-0659-13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172

3-18
Cisco 10008 Router Hardware Installation Guide
OL-0659-13
Chapter 3
Installing the Cisco 10008 Router
Connecting DC Power to the Cisco 10008 Router
Recommended Tools and Supplies
Table 3-2
lists the tools and supplies that you need to connect the Cisco 10008 router to DC power
sources.
Use the following procedure to connect the chassis to a DC power source:
Figure 3-16
Setting DC PEM Switches to the Off Position
Step 1
Set the DC PEM switch (or switches) to the Off position (
Figure 3-16
).
Warning
This product requires short-circuit (overcurrent) protection, to be provided as part of the building
installation. Install only in accordance with national and local wiring regulations.
Statement 1045
Table 3-2
Tools and Supplies
Quantity
Description
Comments
1
Flat-blade screwdriver
1
Wire stripping tool
2 or 4 (length
varies)
2
10 AWG (minimum) wire
cables
Tie wraps
Cables must reach from the Cisco 10008 router to the DC power source.
Two cables are needed for a single DC power source.
Four cables are needed for two DC power sources.
The end of the cable intended to be connected to the chassis needs to
have insulation stripped back not more than 0.4 in. (10 mm).
30019
1
3
2
4
0A
PROCESSOR ONLY
0B
5
6
7
8
PROCESSOR ONLY
POWER
FAULT
MISWIRE
POWER
FAULT
MISWIRE
C10000
6CT3
C10000
6CT3
C10000
6CT3
C10000
6CT3
CISCO
10000
CISCO
10000
CISCO
10000
0
5
4
3
2
1
CISCO
10000
0
5
4
3
2
1
PERFORMANCE ROUTING ENGINE
ALARMS
CISCO
10000
PERFORMANCE ROUTING ENGINE
ALARMS
CISCO
10000
CISCO
10000
0
5
4
3
2
1
CISCO
10000
0
5
4
3
2
1
CISCO
10000
0
5
4
3
2
1
CISCO
10000
When hot swapping this fan tray,
removal and replacement must
be done in under two minutes or
system shutdown will occur.
CAUTION
POWER
FAULT
MISWIRE