Cisco ESR10008 Hardware Installation Guide - Page 20

Blower Module, Power Entry Modules, Connector Ports, PCMCIA Card Slots,

Page 20 highlights

Cisco 10008 Router Hardware Description Chapter 1 Cisco 10008 Router Overview The Cisco 10008 chassis is designed for mounting in 19-inch or (optional) 23-inch equipment racks, and contains the following components: • Blower Module, page 1-6 • Power Entry Modules, page 1-6 • Connector Ports, page 1-9 • PCMCIA Card Slots, page 1-10 Blower Module The Cisco 10008 router uses a blower module (Figure 1-3) containing four fans to supply cooling air to the chassis. Figure 1-3 Blower Module 30002 FANS OK FAN FAILURE MULTIFAN FAILURE WrbseyemhsdetoeonvmnahelsoaihtnnCusduwtAdnarUodepwTeppnIrliaOntcwwgNeioltmlhmoiescnincftauumntre.utsrsaotyr, The blower module is located at the top of the chassis and connects to a connector on the chassis. 1. Four internal fans draw cooling air into the front of the chassis and directs it across the internal components to maintain an acceptable operating temperature. 2. The air is exhausted through openings in the rear of the chassis. Although the blower module supports hot-swapping and can be replaced without interruption to system operation, do not power down the system without the blower unit for more than a few minutes to prevent overheating. Power Entry Modules The DC PEM provides filtering and supplies DC power to the chassis electronics (Figure 1-4). DC PEMs receive input power (-48 VDC from building centralized power source) through terminal block connections located on the rear of the chassis. Table 1-1 describes the LEDs on the DC PEM. Cisco 10008 Router Hardware Installation Guide 1-6 OL-0659-13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172

1-6
Cisco 10008 Router Hardware Installation Guide
OL-0659-13
Chapter 1
Cisco 10008 Router Overview
Cisco 10008 Router Hardware Description
The Cisco
10008 chassis is designed for mounting in 19-inch or (optional) 23-inch equipment racks, and
contains the following components:
Blower Module, page 1-6
Power Entry Modules, page 1-6
Connector Ports, page 1-9
PCMCIA Card Slots, page 1-10
Blower Module
The Cisco 10008 router uses a blower module (
Figure 1-3
) containing four fans to supply cooling air to
the chassis.
Figure 1-3
Blower Module
The blower module is located at the top of the chassis and connects to a connector on the chassis.
1.
Four internal fans draw cooling air into the front of the chassis and directs it across the internal
components to maintain an acceptable operating temperature.
2.
The air is exhausted through openings in the rear of the chassis.
Although the blower module supports hot-swapping and can be replaced without interruption to system
operation, do not power down the system without the blower unit for more than a few minutes to prevent
overheating.
Power Entry Modules
The DC PEM provides filtering and supplies DC power to the chassis electronics (
Figure 1-4
). DC PEMs
receive input power (–48 VDC from building centralized power source) through terminal block
connections located on the rear of the chassis.
Table 1-1
describes the LEDs on the DC PEM.
30002
FANS
OK
FAN
FAILURE
MULTI-
FAN
FAILURE
When hot swapping this fan tray,
removal and replacement must
be done in under two minutes or
system shutdown will occur.
CAUTION