Dell Brocade 6520 MIB Reference Supporting Fabric OS v7.1.0 - Page 129

Table 39

Page 129 highlights

Physical entity group 5 TABLE 39 Object and OID Access entPhysicalContainedIn Read only 1.3.6.1.2.1.47.1.1.1.1.4 entPhysicalClass Read only 1.3.6.1.2.1.47.1.1.1.1.5 Description The value of entPhysicalIndex for the physical entity that "contains" this physical entity. A value of 0 indicates this physical entity is not contained in any other physical entity. Note that the set of containment relationships define a strict hierarchy; that is, recursion is not allowed. In the event a physical entity is contained by more than one physical entity (for example, double-wide modules), this object should identify the containing entity with the lowest value of entPhysicalIndex. Value 0 for chassis entry. All containers have ContainedIn set to 1. All FRUs are contained in their respective slot container entries. An indication of the general hardware type of the physical entity. An agent should set this object to the standard enumeration value that most accurately indicates the general class of the physical entity, or the primary class if there is more than one. If no appropriate standard registration identifier exists for this physical entity, then the value other (1) is returned. If the value is unknown by this agent, then the value unknown (2) is returned. Brocade 300 switches can have the following hierarchy of physical objects: • Chassis: One entry (one row) • Container: One entry for each FRU slot (one blade, one power supply, three fans) • Module: One entry for blades, one entry for power supply, and three entries for fans Brocade 5100 switches can have the following hierarchy of physical objects: • Chassis: One entry (one row) • Container: One entry for each FRU slot (one blade, two power supplies, two fans) • Module: One entry for blades, two entries for power supplies, and two entries for fans Brocade 5300 switches can have the following hierarchy of physical objects: • Chassis: One entry (one row) • Container: One entry for each FRU slot (one blade, two power supplies, three fans) • Module: One entry for blades, two entries for power supplies, and three entries for fans Fabric OS MIB Reference 109 53-1002750-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336
  • 337
  • 338
  • 339
  • 340
  • 341
  • 342
  • 343
  • 344
  • 345
  • 346
  • 347
  • 348
  • 349
  • 350
  • 351
  • 352
  • 353
  • 354
  • 355
  • 356
  • 357
  • 358
  • 359
  • 360
  • 361
  • 362
  • 363
  • 364
  • 365
  • 366
  • 367
  • 368
  • 369
  • 370

Fabric OS MIB Reference
109
53-1002750-01
Physical entity group
5
entPhysicalContainedIn
1.3.6.1.2.1.47.1.1.1.1.4
Read only
The value of entPhysicalIndex for the physical entity that “contains” this
physical entity. A value of 0 indicates this physical entity is not
contained in any other physical entity. Note that the set of containment
relationships define a strict hierarchy; that is, recursion is not allowed.
In the event a physical entity is contained by more than one physical
entity (for example, double-wide modules), this object should identify
the containing entity with the lowest value of entPhysicalIndex.
Value 0 for chassis entry. All containers have ContainedIn set to 1. All
FRUs are contained in their respective slot container entries.
entPhysicalClass
1.3.6.1.2.1.47.1.1.1.1.5
Read only
An indication of the general hardware type of the physical entity.
An agent should set this object to the standard enumeration value that
most accurately indicates the general class of the physical entity, or the
primary class if there is more than one.
If no appropriate standard registration identifier exists for this physical
entity, then the value
other (1) is returned. If the value is unknown by this agent, then the
value unknown (2) is returned.
Brocade 300 switches can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one blade, one power
supply, three fans)
Module: One entry for blades, one entry for power supply, and
three entries for fans
Brocade 5100 switches can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one blade, two power
supplies, two fans)
Module: One entry for blades, two entries for power supplies, and
two entries for fans
Brocade 5300 switches can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one blade, two power
supplies, three fans)
Module: One entry for blades, two entries for power supplies, and
three entries for fans
TABLE 39
Object and OID
Access
Description