to -13.20 VDC
View all Dell OptiPlex GX1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
-12 VDC -10.80 to -13.20 VDC 0.3 A (low-profile computers); 0.3 A (midsize and mini tower computers) -5 VDC -4.50 to -5.50 VDC 0.3 A (low-profile computers); 0.3 A (midsize and mini tower computers) +5 VFP3 +4.75 to +5.25 VDC 10 mA 3 VFP (volts flea power) - sometimes called "standby power." The power-supply output voltages can be measured at the back (wire side) of the connectors without disconnecting them. Figures 1-15 through 1-17 show the wire side of the connectors. -5 VDC (white) +5 VDC (red) common (black) +5 VDC (red) common (black) +5 VDC (red) common (black) PSON# 1 (gray) TFSC2 (brown) +5 VDC (red) 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 +5 VDC (red) common (black) common (black) +5 VDC (red) common (black) PWRGOOD 3 (orange) common (black) -12 VDC (blue) +12 VDC (yellow) +5 VFP (purple) 1 Pin 11 - PSON# should measure between +4 and +5 VDC except when the power button on the front panel is pressed, taking PSON# to its active-low state. 2 Pin 19 - Thermal fan-speed control (TFSC) is a power-supply input signal used to control the power-supply fan speed. 3 Pin 5 - PWRGOOD should measure between +4 and +5 VDC when the power supply is on and operating to indicate that all power-supply output voltages are within ranges specified in Table 1-4. System Overview 1-25