Dell OptiPlex GX1 Dell OptiPlex GX1/GX1p Managed PC and OptiPlex NX1 Net PC S - Page 71

LPHµRIµGD\²QRW²

Page 71 highlights

MS-DOS unable to locate specific track on diskette or hard-disk drive. Defective diskette or hard-disk drive. System could not find Faulty diskette or hardparticular address mark disk drive. on disk. System board chip faulty. Defective system board. Backup battery low. Defective battery or faulty chip (defective system board). Time or Date setting in System Setup program incorrect or system battery bad. Incorrect Time or Date settings or defective system battery. Timer circuit on system Defective system board. board malfunctioning. Keyboard/mouse controller malfunctioning or one or more DIMMs improperly seated. MS-DOS cannot write to diskette or hard-disk drive. Improperly seated DIMMs or faulty keyboard/mouse controller chip (defective system board). Faulty diskette or harddisk drive. Beep Codes and Error Messages 3-7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

Beep Codes and Error Messages
3-7
6HHN²HUURU
MS-DOS unable to
locate specific track on
diskette or hard-disk
drive.
Defective diskette or
hard-disk drive.
6HHN²RSHUDWLRQ²
IDLOHG
System could not find
particular address mark
on disk.
Faulty diskette or hard-
disk drive.
6KXWGRZQ²
IDLOXUH
System board chip
faulty.
Defective system board.
7LPHµRIµGD\²
FORFN²VWRSSHG
Backup battery low.
Defective battery or
faulty chip (defective
system board).
7LPHµRIµGD\²QRW²
VHW
Time
or
Date
setting in
System Setup program
incorrect or system bat-
tery bad.
Incorrect
Time
or
Date
settings or defective
system battery.
7LPHU²FKLS²
FRXQWHU²º²
IDLOHG
Timer circuit on system
board malfunctioning.
Defective system board.
8QH[SHFWHG²
LQWHUUXSW²LQ²
SURWHFWHG²PRGH
Keyboard/mouse con-
troller malfunctioning or
one or more DIMMs
improperly seated.
Improperly seated
DIMMs or faulty
keyboard/mouse
controller chip (defective
system board).
:ULWH²IDXOW
:ULWH²IDXOW²RQ²
VHOHFWHG²GULYH
MS-DOS cannot write
to diskette or hard-disk
drive.
Faulty diskette or hard-
disk drive.
7DEOH±¶´µ³±±6\VWHP±(UURU±0HVVDJHV
±²FRQWLQXHG³
0HVVDJH
’HILQLWLRQ
3UREDEOH²&DXVHV