Dell PowerEdge R240 EMC PowerEdge R240 Installation and Service Manual - Page 51

Removing a cabled drive, Installing a cabled drive

Page 51 highlights

Next steps 1. Replace a 3.5-inch drive carrier. 2. Follow the procedure listed in After working inside your system. Removing a cabled drive Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system. CAUTION: Mixing drives from previous generations of PowerEdge servers is not supported. Steps 1. Disconnect the power and data cable connector that is connected to the drive. 2. Press the release button, and slide the drive out of the drive slot. Figure 29. Removing a cabled drive Next steps 1. Install the drive into the drive carrier. Installing a cabled drive Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system. CAUTION: Mixing drive carriers from other generations of PowerEdge servers is not supported. NOTE: When installing a drive into the drive carrier, ensure that the screws are torqued to 4 inch-pounds. Steps 1. Insert the drive into the drive slot until the release button clicks into place. PowerEdge R240 installing and removing system components 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

Next steps
1.
Replace a 3.5-inch drive carrier
.
2.
Follow the procedure listed in
After working inside your system
.
Removing a cabled drive
Prerequisites
1.
Follow the safety guidelines listed in the
Safety instructions
.
2.
Follow the procedure listed in the
Before working inside your system
.
CAUTION:
Mixing drives from previous generations of PowerEdge servers is not supported.
Steps
1.
Disconnect the power and data cable connector that is connected to the drive.
2.
Press the release button, and slide the drive out of the drive slot.
Figure 29. Removing a cabled drive
Next steps
1.
Install the drive into the drive carrier
.
Installing a cabled drive
Prerequisites
1.
Follow the safety guidelines listed in the
Safety instructions
.
2.
Follow the procedure listed in the
Before working inside your system
.
CAUTION:
Mixing drive carriers from other generations of PowerEdge servers is not supported.
NOTE:
When installing a drive into the drive carrier, ensure that the screws are torqued to 4 inch-pounds.
Steps
1.
Insert the drive into the drive slot until the release button clicks into place.
PowerEdge R240 installing and removing system components
51