Dell PowerEdge R6525 EMC Installation and Service Manual - Page 142

System weight, Processor specifications, PSU specifications, Supported operating systems

Page 142 highlights

System weight Table 54. PowerEdge R6525 system weight System configuration 4 x 3.5-inch 8 x 2.5-inch 10 x 2.5-inch Maximum weight (with all drives/SSDs) 21.8 kg (48.06 lb) 19.2 kg (42.33 lb) 21.8 kg (48.06 lb) Processor specifications Table 55. PowerEdge R6525 processor specifications Supported processor AMD EPYC 7002 series processors Number of processors supported Two PSU specifications The PowerEdge R6525 system supports up to two AC or DC power supply units (PSUs). WARNING: Instructions for the qualified electricians only: System using -(48-60) V DC or 240 V DC power supplies are intended for restricted access locations in accordance with Articles 110-5, 110-6, 110-11, 110-14, and 110-17 of the National Electrical Code, American National Standards Institute (ANSI)/National Fire Protection Association (NFPA) 70. 240 V DC power supplies shall be connected to the 240 V DC outlet from certified power distribution units if applicable in country of use. Power supply cords/jumper cords and the associated plugs/inlets/connectors shall have appropriate electrical ratings referencing the rating label on the system when used for connection. Table 56. PowerEdge R6525 PSU specifications PSU Class Heat dissipation (maximum) 800 W AC mixed mode Platinum 3139 BTU/hr 800 W HVDC Platinum 3139 BTU/hr 800 W HVDC mixed Platinum mode 3000 BTU/hr 1400 W AC mixed mode Platinum 5459 BTU/hr 1400 W HVDC Platinum 5459 BTU/hr 1400 W HVDC mixed Platinum mode 5250 BTU/hr Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Voltage 100 -240 V AC, autoranging 240 V DC 240 V DC 100 -240 V AC, autoranging 240 V DC 240 V DC Current 9.2 - 4.7 A 3.8 A 3.8 A 12 - 8 A 6.6 A 6.6 A NOTE: When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA. Supported operating systems The PowerEdge R6525 supports the following operating systems: 142 Technical specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

System weight
Table 54. PowerEdge R6525 system weight
System configuration
Maximum weight (with all drives/SSDs)
4 x 3.5-inch
21.8 kg (48.06 lb)
8 x 2.5-inch
19.2 kg (42.33 lb)
10 x 2.5-inch
21.8 kg (48.06 lb)
Processor specifications
Table 55. PowerEdge R6525 processor specifications
Supported processor
Number of processors supported
AMD EPYC 7002 series processors
Two
PSU specifications
The PowerEdge R6525 system supports up to two AC or DC power supply units (PSUs).
WARNING:
Instructions for the qualified electricians only:
System using -(48-60) V DC or 240 V DC power supplies are intended for restricted access locations in accordance with
Articles 110-5, 110-6, 110-11, 110-14, and 110-17 of the National Electrical Code, American National Standards Institute
(ANSI)/National Fire Protection Association (NFPA) 70.
240 V DC power supplies shall be connected to the 240 V DC outlet from certified power distribution units if applicable
in country of use.
Power supply cords/jumper cords and the associated plugs/inlets/connectors shall have appropriate electrical ratings
referencing the rating label on the system when used for connection.
Table 56. PowerEdge R6525 PSU specifications
PSU
Class
Heat dissipation
(maximum)
Frequency
Voltage
Current
800 W AC mixed
mode
Platinum
3139 BTU/hr
50/60 Hz
100 -240 V AC,
autoranging
9.2 - 4.7 A
800 W HVDC
Platinum
3139 BTU/hr
50/60 Hz
240 V DC
3.8 A
800 W HVDC mixed
mode
Platinum
3000 BTU/hr
50/60 Hz
240 V DC
3.8 A
1400 W AC mixed
mode
Platinum
5459 BTU/hr
50/60 Hz
100 -240 V AC,
autoranging
12 - 8 A
1400 W HVDC
Platinum
5459 BTU/hr
50/60 Hz
240 V DC
6.6 A
1400 W HVDC mixed
mode
Platinum
5250 BTU/hr
50/60 Hz
240 V DC
6.6 A
NOTE:
When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system
power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA.
Supported operating systems
The PowerEdge R6525 supports the following operating systems: