Table 47. Configuration 1: R1a continued, Card type, Slot priority, Maximum number of cards

Page 95 highlights

Table 47. Configuration 1: R1a (continued) Card type Slot priority Dell BOSS Adapter 1 Samsung (PCIE SSD) 1 Intel (PCIE SSD) 1 Dell Front PERC Internal Slot Broadcom (OCP: 25 Gb) Internal Slot QLogic (OCP: 25 Gb) Internal Slot Mellanox (OCP: 25 Gb) Internal Slot Intel (OCP: 10 Gb) Internal Slot Broadcom (OCP: 10 Gb) Internal Slot QLogic (OCP: 10 Gb) Internal Slot Broadcom (OCP: 1 Gb) Internal Slot Intel (OCP: 1 Gb) Internal Slot Table 48. Configuration 2: R2a + R3a Card type Slot priority Dell BOSS Adapter 2, 1, 3 T4 GPU (Nvidia) 2, 1, 3 Mellanox (NIC: 100 Gb) 2, 1, 3 Intel (NIC: 25 Gb) 2, 1, 3 Mellanox (NIC: 25 Gb) 2, 1, 3 Broadcom (NIC: 25 Gb) 2, 1, 3 QLogic (NIC: 25 Gb) 2, 1, 3 Emulex (HBA: FC32) 2, 1, 3 QLogic (HBA: FC32) 2, 1, 3 Emulex (HBA: FC16) 2, 1, 3 QLogic (HBA: FC16) 2, 1, 3 Intel (NIC: 10 Gb) 2, 1, 3 Broadcom (NIC: 10 Gb) 2, 1, 3 QLogic (NIC: 10 Gb) 2, 1, 3 Intel (NIC: 1 Gb) 2, 1, 3 Broadcom (NIC: 1 Gb) 2, 1, 3 Mellanox (NIC: HDR100 VPI) 2, 1, 3 Dell PERC Adapter 2, 1, 3 Samsung (PCIe SSD) 2, 1, 3 Intel (PCIe SSD) 2, 1, 3 Maximum number of cards 1 1 1 1 1 1 1 1 1 1 1 1 Maximum number of cards 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Installing and removing system components 95

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

Table 47. Configuration 1: R1a (continued)
Card type
Slot priority
Maximum number of cards
Dell BOSS Adapter
1
1
Samsung (PCIE SSD)
1
1
Intel (PCIE SSD)
1
1
Dell Front PERC
Internal Slot
1
Broadcom (OCP: 25 Gb)
Internal Slot
1
QLogic (OCP: 25 Gb)
Internal Slot
1
Mellanox (OCP: 25 Gb)
Internal Slot
1
Intel (OCP: 10 Gb)
Internal Slot
1
Broadcom (OCP: 10 Gb)
Internal Slot
1
QLogic (OCP: 10 Gb)
Internal Slot
1
Broadcom (OCP: 1 Gb)
Internal Slot
1
Intel (OCP: 1 Gb)
Internal Slot
1
Table 48. Configuration 2: R2a + R3a
Card type
Slot priority
Maximum number of cards
Dell BOSS Adapter
2, 1, 3
1
T4 GPU (Nvidia)
2, 1, 3
3
Mellanox (NIC: 100 Gb)
2, 1, 3
3
Intel (NIC: 25 Gb)
2, 1, 3
3
Mellanox (NIC: 25 Gb)
2, 1, 3
3
Broadcom (NIC: 25 Gb)
2, 1, 3
3
QLogic (NIC: 25 Gb)
2, 1, 3
3
Emulex (HBA: FC32)
2, 1, 3
3
QLogic (HBA: FC32)
2, 1, 3
3
Emulex (HBA: FC16)
2, 1, 3
3
QLogic (HBA: FC16)
2, 1, 3
3
Intel (NIC: 10 Gb)
2, 1, 3
3
Broadcom (NIC: 10 Gb)
2, 1, 3
3
QLogic (NIC: 10 Gb)
2, 1, 3
3
Intel (NIC: 1 Gb)
2, 1, 3
3
Broadcom (NIC: 1 Gb)
2, 1, 3
3
Mellanox (NIC: HDR100 VPI)
2, 1, 3
3
Dell PERC Adapter
2, 1, 3
3
Samsung (PCIe SSD)
2, 1, 3
3
Intel (PCIe SSD)
2, 1, 3
3
Installing and removing system components