Dell PowerEdge R6525 EMC Installation and Service Manual - Page 16

Inside the system, Locating the Express Service Code and Service Tag

Page 16 highlights

Inside the system Figure 10. Inside the system 1. Drive backplane 3. Dual fan module (4) 5. Memory DIMM socket for processor 2 (B1) 7. Riser 3 9. Power supply unit (PSU 2) 11. IDSDM/Internal USB card port 13. Heat sink for processor 1 15. xGMI cables 2. Rear mounting front PERC module 4. System board 6. Heat sink for processor 2 8. Intrusion switch 10. Power supply unit (PSU 1) 12. Riser 2 14. Memory DIMM socket for processor 1 (A1) Locating the Express Service Code and Service Tag The unique Express Service Code and Service Tag is used to identify the system. The information tag is located on the front of the system that includes system information such as Service Tag, Express Service Code, Manufacture date, NIC, MAC address, QRL label, and so on. If you have opted for the secure default access to iDRAC, the Information tag also contains the iDRAC secure default password. If you have opted for iDRAC Quick Sync 2, the Information tag also contains the OpenManage Mobile (OMM) label, where administrators can configure, monitor, and troubleshoot the PowerEdge servers. 16 System overview

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

Inside the system
Figure 10. Inside the system
1.
Drive backplane
2.
Rear mounting front PERC module
3.
Dual fan module (4)
4.
System board
5.
Memory DIMM socket for processor 2 (B1)
6.
Heat sink for processor 2
7.
Riser 3
8.
Intrusion switch
9.
Power supply unit (PSU 2)
10.
Power supply unit (PSU 1)
11.
IDSDM/Internal USB card port
12.
Riser 2
13.
Heat sink for processor 1
14.
Memory DIMM socket for processor 1 (A1)
15.
xGMI cables
Locating the Express Service Code and Service
Tag
The unique Express Service Code and Service Tag is used to identify the system.
The information tag is located on the front of the system that includes system information such as Service Tag, Express Service Code,
Manufacture date, NIC, MAC address, QRL label, and so on. If you have opted for the secure default access to iDRAC, the Information tag
also contains the iDRAC secure default password. If you have opted for iDRAC Quick Sync 2, the Information tag also contains the
OpenManage Mobile (OMM) label, where administrators can configure, monitor, and troubleshoot the PowerEdge servers.
16