Dell PowerSwitch S4820T FTOS 8.3.19.0 Command Line Reference Guide for the S48 - Page 1404
sflow polling-interval Interface
View all Dell PowerSwitch S4820T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1404 highlights
www.dell.com | support.dell.com Parameters Defaults Command Modes Command History Usage Information Related Commands interval value Enter the interval value in seconds. Range: 15 to 86400 seconds Default: 20 seconds 20 seconds CONFIGURATION Version 8.3.19.0 Version 8.3.7.0 Version 8.2.1.0 Version 8.1.1.0 Version 7.7.1.0 Version 7.6.1.0 Version 6.2.1.1 Introduced on S4820T Introduced on S4810 Introduces on S-Series Stacking Introduced on E-Series ExaScale Introduced on S-Series Introduced on C-Series Introduced on E-Series The polling interval for an interface is the maximum number of seconds between successive samples of counters to be sent to the collector. This command changes the global default counter polling (20 seconds) interval. You can configure an interface to use a different polling interval. sflow polling-interval (Interface) Set the polling interval for an interface sflow polling-interval (Interface) c e s Set the sFlow polling interval at an interface (overrides the global-level setting.) Syntax Parameters Defaults Command Modes Command History sflow polling-interval interval value To return to the default, use the no sflow polling-interval interval command. interval value Enter the interval value in seconds. Range: 15 to 86400 seconds Default: The global counter polling interval The same value as the current global default counter polling interval INTERFACE Version 8.3.19.0 Introduced on S4820T Version 8.3.7.0 Introduced on S4810 1404 | sFlow