Dell PowerSwitch S4820T FTOS 8.3.19.0 Command Line Reference Guide for the S48 - Page 1514
vlan-stack dot1p-mapping, vlan-stack protocol-type
View all Dell PowerSwitch S4820T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1514 highlights
www.dell.com | support.dell.com 5 FTOS# Active M Gi 13/4 M Po1(Gi 13/14-15) M Gi 13/18 M Gi 13/5 vlan-stack dot1p-mapping c s Map C-Tag dot1p values to a S-Tag dot1p value. C-Tag values may be separated by commas and dashed ranges are permitted. Dynamic Mode CoS overrides any Layer 2 QoS configuration in case of conflicts. Syntax vlan-stack dot1p-mapping c-tag-dot1p values sp-tag-dot1p value Parameters c-tag-dot1p value sp-tag-dot1p value Enter the keyword followed by the customer dot1p value that will be mapped to a service provider do1p value. Range: 0 to 7 Enter the keyword followed by the service provider dot1p value. Range: 0 to 7 Defaults None Command Modes INTERFACE Command History Version 8.3.19.0 Version 8.3.7.0 Version 8.3.1.0 Introduced on S4820T Introduced on S4810 Introduced on C-Series and S-Series. vlan-stack protocol-type c e s Define the Stackable VLAN Tag Protocol Identifier (TPID) for the outer VLAN tag (also called the VMAN tag). If you do not configure this command, FTOS assigns the value 0x9100. Syntax Parameters Defaults vlan-stack protocol-type number number Enter the hexadecimal number as the Stackable VLAN tag. On the E-Series: FTOS accepts the Most Significant Byte (MSB) and then appends zeros for the Least Significant Byte (LSB). On the C-Series and S-Series: You may specify both bytes of the 2-byte S-Tag TPID. E-Series Range: 0 to FF C-Series and S-Series Range: 0 to FFFF Default: 9100 0x9100 1514 | VLAN Stacking