Powering Off the Enclosure

Page 120 highlights

The POWERON BAY and REBOOT BAY commands have been extended to allow an argument which sets blade PC boot order for that boot only. These settings are the same as the SET BAY BOOT ONCE command. To determine if any boot order changes are pending for a specific blade, use the SHOW BAY INFO command. The "Pending Boot Order:" status line will show any pending changes to the boot order, either one-time or permanent. Powering Off the Enclosure CAUTION: Powering off the enclosure removes all power from the blade PCs and ends all open sessions. After powering off the enclosure, you can only power on the enclosure if you have physical access to the enclosure. To power off the enclosure using the Web-based user interface: 1. Click the Enclosure tab. 2. Click Virtual Buttons. 3. Click Power Off. 4. Click Apply. To power off the enclosure using the CLI, type: POWEROFF ENCLOSURE This command attempts to perform a graceful shutdown of the enclosure by powering off each blade PC and then powering off the enclosure. After 5 minutes, the command powers down all components of the system immediately if they are not already powered off. 112 Chapter 8 Performing Advanced Functions ENWW

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147

The POWERON BAY and REBOOT BAY commands have been extended to allow an argument which
sets blade PC boot order for that boot only. These settings are the same as the SET BAY BOOT ONCE
command.
To determine if any boot order changes are pending for a specific blade, use the SHOW BAY INFO
command. The “Pending Boot Order:” status line will show any pending changes to the boot order, either
one-time or permanent.
Powering Off the Enclosure
CAUTION:
Powering off the enclosure removes all power from the blade PCs and ends all open
sessions. After powering off the enclosure, you can only power on the enclosure if you have physical
access to the enclosure.
To power off the enclosure using the Web-based user interface:
1.
Click the
Enclosure
tab.
2.
Click
Virtual Buttons
.
3.
Click
Power Off
.
4.
Click
Apply
.
To power off the enclosure using the CLI, type:
POWEROFF ENCLOSURE
This command attempts to perform a graceful shutdown of the enclosure by powering off each blade
PC and then powering off the enclosure. After 5 minutes, the command powers down all components
of the system immediately if they are not already powered off.
112
Chapter 8
Performing Advanced Functions
ENWW