HP BladeSystem bc2800 HP BladeSystem PC Blade Enclosure Integrated Administrat - Page 89

From: Enclosure IA-00508BEBA571 <[email protected]&gt

Page 89 highlights

● Blade thermal change ● Blade fault NOTE: If the enclosure has a switch installed, it can take up to 60 seconds before the system will send out an AlertMail after a system boot up. Events generated within this period of time will be sent out when the switch has come online. All e-mails have the following header: Subject: HP AlertMail-SEQ: SUBJECT Date: Date in standard format From: Enclosure ENCLOSURE-NAME To: RECEIVER MAILBOX Where SEVERITY is one of the following: ● Highest ● # CRITICAL ● # WARNING ● # NOTICE ● # INFO ● Lowest Example e-mail: ----SAMPLE START---- Subject: HP AlertMail-010: (CRITICAL) Power Supply #1: Failed Date: Wed, 23 Apr 2003 15:02:22 +0200 From: Enclosure IA-00508BEBA571 To: user@userdomain X-OS: HP Integrated Administrator X-Priority: 1 Content-Type: text/plain; charset=us-ascii EVENT (26 May 07:09): Power Supply #1 Status has changed to: Failed Enclosure, IA-00508BEBA571, has detected that a power supply in bay 1 has changed from status OK to Failed. The power supply should be replaced with the appropriate spare part. You can ensure that the center wall assembly is operating correctly by swapping the two power supplies. Make sure that there are no bent pins on the power supply connectors before reinserting and that each power supply is fully seated. ENWW Setting Up AlertMail 81

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147

Blade thermal change
Blade fault
NOTE:
If the enclosure has a switch installed, it can take up to 60 seconds before the system will send
out an AlertMail after a system boot up. Events generated within this period of time will be sent out when
the switch has come online.
All e-mails have the following header:
Subject: HP AlertMail-SEQ: <SEVERITY> SUBJECT
Date: Date in standard format
From: Enclosure ENCLOSURE-NAME <enclosure-name@domain>
To: RECEIVER MAILBOX
Where SEVERITY is one of the following:
Highest
# CRITICAL
# WARNING
# NOTICE
# INFO
Lowest
Example e-mail:
----SAMPLE START----
Subject: HP AlertMail-010: (CRITICAL) Power Supply #1: Failed
Date: Wed, 23 Apr 2003 15:02:22 +0200
From: Enclosure IA-00508BEBA571 <[email protected]>
To: user@userdomain
X-OS: HP Integrated Administrator
X-Priority: 1
Content-Type: text/plain; charset=us-ascii
EVENT (26 May 07:09): Power Supply #1 Status has changed to: Failed
Enclosure, IA-00508BEBA571, has detected that a power supply in bay 1 has
changed from status OK to Failed.
The power supply should be replaced with the appropriate spare part. You
can ensure that the center wall assembly is operating correctly by swapping
the two power supplies. Make sure that there are no bent pins on the power
supply connectors before reinserting and that each power supply is fully
seated.
ENWW
Setting Up AlertMail
81