HP GbE2c HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Refere - Page 57

Link status information, The following table describes the RMON Event Information parameters.

Page 57 highlights

RMON Event group configuration: Index ----- 1 2 3 4 5 10 11 15 100 Type ---both none log trap both both both both both Last Sent 0D: 0H: 1M:20S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S 0D: 0H: 0M: 0S Description Event_1 Event_2 Event_3 Event_4 Log and trap event for Link Down Log and trap event for Link Up Send log and trap for icmpInMsg Send log and trap for icmpInEchos Event_100 The following table describes the RMON Event Information parameters. Table 43 RMON Event Information Menu /info/rmon/event Command Usage Index Type Last Sent Description Displays the index number that identifies each event instance. Displays the type of notification provided for this event, as follows: none, log, trap, both. Displays the time that passed since the last switch reboot, when the most recent event was triggered. This value is cleared when the switch reboots. Displays a text description of the event. Link status information Command: /info/link Port Speed Duplex Flow Ctrl Link TX-----RX-- ------ 1 1000 any yes yes down 2 1000 any yes yes down 3 1000 full yes yes down 4 1000 full yes yes down 5 1000 any yes yes down 6 1000 any yes yes down 7 1000 any yes yes down 8 1000 full no yes up 9 1000 full yes yes down 10 1000 full yes yes down 11 1000 any yes yes down 12 1000 any yes yes down 13 1000 any yes yes down 14 1000 any yes yes down 15 1000 any yes yes down 16 1000 any yes yes down 17 100 full yes yes down 18 100 full yes yes down 19 100 full yes yes down 20 100 full yes yes down 21 1000 full yes yes down 22 any any yes yes down 23 any any yes yes down 24 any any yes yes down Information Menu 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175

Information Menu 57
RMON Event group configuration:
Index
Type
Last Sent
Description
-----
----
----------------
---------------------------------
1
both
0D: 0H: 1M:20S
Event_1
2
none
0D: 0H: 0M: 0S
Event_2
3
log
0D: 0H: 0M: 0S
Event_3
4
trap
0D: 0H: 0M: 0S
Event_4
5
both
0D: 0H: 0M: 0S
Log and trap event for Link Down
10
both
0D: 0H: 0M: 0S
Log and trap event for Link Up
11
both
0D: 0H: 0M: 0S
Send log and trap for icmpInMsg
15
both
0D: 0H: 0M: 0S
Send log and trap for icmpInEchos
100
both
0D: 0H: 0M: 0S
Event_100
The following table describes the RMON Event Information parameters.
Table 43
RMON Event Information Menu
/info/rmon/event
Command
Usage
Index
Displays the index number that identifies each event instance.
Type
Displays the type of notification provided for this event, as follows:
none, log, trap, both
.
Last Sent
Displays the time that passed since the last switch reboot, when the most recent event was triggered.
This value is cleared when the switch reboots.
Description
Displays a text description of the event.
Link status information
Command:
/info/link
------------------------------------------------------------------
Port
Speed
Duplex
Flow Ctrl
Link
----
-----
--------
--TX-----RX--
------
1
1000
any
yes
yes
down
2
1000
any
yes
yes
down
3
1000
full
yes
yes
down
4
1000
full
yes
yes
down
5
1000
any
yes
yes
down
6
1000
any
yes
yes
down
7
1000
any
yes
yes
down
8
1000
full
no
yes
up
9
1000
full
yes
yes
down
10
1000
full
yes
yes
down
11
1000
any
yes
yes
down
12
1000
any
yes
yes
down
13
1000
any
yes
yes
down
14
1000
any
yes
yes
down
15
1000
any
yes
yes
down
16
1000
any
yes
yes
down
17
100
full
yes
yes
down
18
100
full
yes
yes
down
19
100
full
yes
yes
down
20
100
full
yes
yes
down
21
1000
full
yes
yes
down
22
any
any
yes
yes
down
23
any
any
yes
yes
down
24
any
any
yes
yes
down