HP Integrity rx4640 Windows Integrity Management Agents Reference - Page 144
Drive Array Physical Drive Status Change. The physical drive in slot %4, port %5
View all HP Integrity rx4640 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 144 highlights
1064 1065 1066 1067 1068 1069 1070 1075 1076 1077 1078 1098 1101 1102 1104 Error Drive Array Physical Drive Status Change. The physical drive in slot %4, port %5, bay %6 with serial number "%7", has a new status of %2.%n(Drive status values: 1=other, 2=ok, 3=failed, 4=predictiveFailure)%n[SNMP TRAP: 3029 in CPQIDA.MIB] Error Drive Array Accelerator Status Change. The array accelerator board attached to the array controller in slot %4 has a new status of %2.%n(Accelerator status values: 1=other, 2=notConfigured, 3=enabled, 4=tmpDisabled, 5=permDisabled)%n [SNMP TRAP: 3025 in CPQIDA.MIB] Error Drive Array Accelerator Bad Data. The array accelerator board attached to the array controller in slot %4 is reporting that it contains bad cached data.%n[SNMP TRAP: 3026 in CPQIDA.MIB] Error Drive Array Accelerator Battery Failed. The array accelerator board attached to the array controller in slot %4 is reporting a battery failure.%n[SNMP TRAP: 3027 in CPQIDA.MIB] Error SCSI Controller Status Change.%nThe SCSI controller in slot %4, SCSI bus %5 has a new status of %2.%n(Controller status values: 1=other, 2=ok, 3=failed)%n[SNMP TRAP: 5005 in CPQSCSI.MIB] Error SCSI Logical Drive Status Change.%nThe SCSI logical drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(Drive status values: 1=other, 2=ok, 3=failed, 4=unconfigured, 5=recovering, 6=readyForRebuild, 7=rebuilding, 8=wrongDrive, 9=badConnect, 10=degraded, 11=disabled)%n [SNMP TRAP: 5021 in CPQSCSI.MIB] Error SCSI Physical Drive Status Change.%nThe SCSI physical drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(Drive status values: 1=other, 2=ok, 3=failed, 4=notConfigured, 5=badCable, 6=missingWasOk, 7=missingWasFailed, 8=predictiveFailure, 9=missingWasPredictiveFailure, 10=offline, 11=missingWasOffline)%n [SNMP TRAP: 5020 in CPQSCSI.MIB] Warning Storage System Fan Status Change.%nThe %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(Fan status values: 1=other, 2=ok, 3=failed, 4=notInstalled, 5=degraded)%n [SNMP TRAP: 8008 in CPQSTSYS.MIB] Error Storage System Temperature Failure.%nThe %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has a failed temperature status. Shutdown the storage system as soon as possible.%n [SNMP TRAP: 8009 in CPQSTSYS.MIB] Warning Storage System Temperature Degraded.%nThe %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 system has a temperature outside the normal operating range.%n [SNMP TRAP: 8010 in CPQSTSYS.MIB] Storage System Temperature OK.%nThe temperature in the %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has returned to the normal Informational operating range.%n [SNMP TRAP: 8011 in CPQSTSYS.MIB] Drive Array Physical Drive Monitoring is not enabled. The physical drive in slot %4, port %5, bay %6 with serial number "%7", does not have drive threshold monitoring Informational enabled. Warning Storage System Side Panel Removed.%nThe side panel has been removed on the %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4.%n [SNMP TRAP: 8013 in CPQSTSYS.MIB] Storage System Side Panel In Place.%nThe side panel has been replaced on the %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4.%n [SNMP Informational TRAP: 8012 in CPQSTSYS.MIB] Warning Storage System Fault Tolerant Power Supply Degraded.%nThe fault tolerant power supply in the %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has a degraded status. Restore power or replace any failed power supply.%n [SNMP TRAP: 8015 in CPQSTSYS.MIB] 144 Management Agents Event Tables