HP Integrity rx4640 Windows Integrity Management Agents Reference - Page 91
Update PDHC FW, MP FW, System FW and the, same XBC. Check CC, Check XBC, Contact HP
View all HP Integrity rx4640 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
8151 8153 8154 8156 8159 8184 8186 8187 8188 8189 8190 8194 8195 8198 8199 8200 8202 8205 8206 8207 8212 A hardware fault is preventing the PDH bus semaphore from being taken/released as expected. Contact HP support personnel to troubleshoot the Cell Board and/or PDH Daughtercard An unknown OS IPMI driver or Manageability Update PDHC FW, MP FW, System FW and the FW bug has occurred. OS IPMI driver to the latest revisions. SAL service to read tokens not functioning properly. Reset the system. Clear SFW NVM. Upgrade system firmware. An XBC is indicating a port failure Validate all of the cells connectivity to the PD Check the XBC chips seating reset the system replace either cells/system backplane Hardware failure: link, crossbar chip, or cell. Check for hardware failures. Reset backplane to re-initialize fabric. An unrecognized backplane is installed. Contact HP Support Personnel to determine why the backplane was unrecognized. CC Write Failure. Contact HP Support personnel to analyze the fabric. CC to XBC link init failure. Contact your HP service representative to check the CC to XBC link CC to XBC link init failure. Contact your HP service representative to check the CC to XBC link CC to XBC link init failure. Contact your HP service representative to check the CC to XBC link CC to XBC link init failure. Contact your HP service representative to check the CC to XBC link The neighbor port is not routable. The port is either: not connected, landmined, in FE, or contains an SBE or LPE. Contact HP Support personnel to analyze the fabric. Fabric access error Contact HP Support personnel to analyze the fabric. Possible crossbar failure Contact HP Support personnel to analyze the crossbar. Hardware in unknown state, or programming Upgrade PM firmware to latest revision. If bug found. already at current revision, replace UGUY board. Hardware in unknown state, or programming Upgrade PM firmware to latest revision. If bug found. already at current revision, replace UGUY board. Debug event. Contact your hp support representative. Either the CC failed to inject the errors, the XBC Check results from other cells connected to the failed to detect them, or PDC could not access the same XBC. Check CC, Check XBC, Contact HP XBC CSR. Support Personnel. Re-configure cabinet to use a valid cabinet number The reporting cell is at a different firmware revision than the cell reported in the data field. A PD cannot be established. Please reprogram the 2 cells to the same firmware revision. A hardware error has occurred. Replace the UGUY board. Platform Events - Table 2 (Windows System Log Event ID, Cause, Recommended Action) 91