Install missing Cabinet Blowers. If proper number, met. Add Bulk Power Supplies, if under - power consumption
View all HP Integrity rx4640 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
7782 7783 7784 7786 7791 7793 7795 7796 7798 7799 7803 7806 7822 7823 7824 7825 7827 Remove entities until Power Requirements are Too many entities installed in the cabinet for the met. Add Bulk Power Supplies, if under Power Available. populated. The number of blowers required is a hard number. It is not dependent upon the number of entities installed in a Cabinet. The Utilities Subsystem is not allowing the Cabinet to power Install missing Cabinet Blowers. If proper number up due to an insufficient number of installed of blowers are installed, troubleshoot blower blowers. presence detection. The number of IO fans required is a hard number. It is not dependent upon the number of entities installed in a Cabinet. The Utilities Subsystem is not allowing the cabinet to power up due to an Install missing IO fans, or if proper number insufficient number of installed IO fans. installed, troubleshoot IO fan presence detection. PDCA (Power Distribution Control Assembly) has failed. Replace the PDCA with proper type (4-wire or 5-wire) PDCA following power distribution control assembly Remove and Replace procedures. Cabinet Blower Failed Replace failed blower module as soon as possible following the Blower Module Remove and Replace Procedures. The PDCA identified has failed. This will be evident by many BPS_FAIL codes and probably Contact HP Support personnel to troubleshoot a AC_DELETED code in the Log. problem Fan failure or fan obstructed If fan is obstructed, remove obstruction. If no obstruction, Contact HP Support personnel to troubleshoot problem. If this code is not accompanied by other codes pointing to the same Bulk Power Supply, then it Contact HP Support personnel to troubleshoot is an internal component failure. problem. Entities were added to the cabinet, increasing the estimated Power Consumption. Or, a non-functional GSP bus entity has become functional, providing previously missing power Purchase and install a Bulk Power Supply, if consumption information. redundancy is desired. The cabinet's 48V power has exceeded an acceptable upper threshold. Contact HP Support personnel to troubleshoot problem. The cabinet's 48V power has fallen below an acceptable lower threshold. Contact HP Support personnel to troubleshoot problem. Cabinet Fan Failed Replace failed cabinet fan module as soon as possible following the Cabinet Fan Module Remove and Replace Procedures. The cabinet's housekeeping power has risen above an acceptable upper threshold. Contact HP Support personnel to troubleshoot problem. The cabinet's housekeeping power has fallen below an acceptable upper threshold. Contact HP Support personnel to troubleshoot problem. Re-configure the BPS in a manner consistent with the explanation in the Problem Description The BPS are installed in an illegal configuration. statement A new revision of Power Supply that requires a Check service notes for firmware revisions and PM3 firmware upgrade was attempting install. compatibility charts. Shutdown and power off the system. Correct air Room Temperature has risen to a critical level. temperature problem. 86 Management Agents Event Tables