HP Integrity rx4640 Windows Integrity Management Agents Reference - Page 98

Check CPU load ordering, didn't catch.

Page 98 highlights

9022 9038 9039 9040 9041 9042 9043 9045 9046 9047 9049 9051 9052 9084 9364 9365 9367 9368 9370 FirmwareError. Capture chassis codes and contact HP Support. Cell hardware problem like PDH memory itself, the coherency controller, the executing CPU or Contact HP Support to troubleshoot the cell and interaction between any of these cell components. either fix it or replace it. Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or interaction Troubleshoot the cell and either fix it or replace between any of these cell components. it. Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or interaction Troubleshoot the cell and either fix it or replace between any of these cell components. it. PDC bug in which PDC thinks it was unable to safely access PDH memory when maybe it really Upgrade PDC if this is found to be the problem could have. and a new PDC image is available. Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or interaction Troubleshoot the cell and either fix it or replace between any of these cell components. it. An error during cell initialization occurred and the cell will not be able to join the partition. Look for other errors in the event log that articulate the exact problem. This is caused by the wrong type of complex profile being loaded. System firmware will default a new partition profile and continue on. Cell hardware problem, like a problem with PDH registers or PDH memory, or a problem with the Troubleshoot the cell and either fix cell or replace concorde or CPU chips. the cell board. Cell hardware problem, like a problem with PDH registers or PDH memory, or a problem with the Troubleshoot the cell and either fix cell or replace concorde or CPU chips. the cell board. Cell hardware problem, like a problem with PDH registers or PDH memory, or a problem with the Troubleshoot the cell and either fix cell or replace concorde or CPU chips. the cell board. Cell hardware problem, like a problem with PDH registers or PDH memory, or a problem with the Troubleshoot the cell and either fix cell or replace concorde or CPU chips. the cell board. Cell Hardware or memory problem that PDC didn't catch. Troubleshoot the cell to find out if page zero contents are screwed up or if hardware is just failed to do the OS write or failed to do the PDC read. Verify that memory is properly written and holds contents at the page zero locations. Perhaps replace the cell board or replace the memory. Check CPU load ordering PDC bug in which PDC is trying to access PDH Upgrade PDC if there is a version of PDC that memory of a cell not in its partition. fixes such a problem. Hardware problem with the PDH riser card. Contact HP Support to confirm the PDH riser card is functioning properly. Hardware connecting cells in the partition experienced a problem such that cells in the partition together can no longer communicate. Troubleshoot the fabric and reseat/replace the cells or cables or backplane if necessary. Hardware problem with the CPU, CC, or PDH flash. Troubleshoot the cell and/or replace it. PDC bug such that PDC didn't log the relocation address. Check for PDC upgrade 98 Management Agents Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151

Capture chassis codes and contact HP Support.
FirmwareError.
9022
Contact HP Support to troubleshoot the cell and
either fix it or replace it.
Cell hardware problem like PDH memory itself,
the coherency controller, the executing CPU or
interaction between any of these cell components.
9038
Troubleshoot the cell and either fix it or replace
it.
Cell hardware problem like PDH memory itself,
the CC chip, the executing CPU or interaction
between any of these cell components.
9039
Troubleshoot the cell and either fix it or replace
it.
Cell hardware problem like PDH memory itself,
the CC chip, the executing CPU or interaction
between any of these cell components.
9040
Upgrade PDC if this is found to be the problem
and a new PDC image is available.
PDC bug in which PDC thinks it was unable to
safely access PDH memory when maybe it really
could have.
9041
Troubleshoot the cell and either fix it or replace
it.
Cell hardware problem like PDH memory itself,
the CC chip, the executing CPU or interaction
between any of these cell components.
9042
An error during cell initialization occurred and
the cell will not be able to join the partition. Look
for other errors in the event log that articulate the
exact problem.
9043
This is caused by the wrong type of complex
profile being loaded. System firmware will
default a new partition profile and continue on.
9045
Troubleshoot the cell and either fix cell or replace
the cell board.
Cell hardware problem, like a problem with PDH
registers or PDH memory, or a problem with the
concorde or CPU chips.
9046
Troubleshoot the cell and either fix cell or replace
the cell board.
Cell hardware problem, like a problem with PDH
registers or PDH memory, or a problem with the
concorde or CPU chips.
9047
Troubleshoot the cell and either fix cell or replace
the cell board.
Cell hardware problem, like a problem with PDH
registers or PDH memory, or a problem with the
concorde or CPU chips.
9049
Troubleshoot the cell and either fix cell or replace
the cell board.
Cell hardware problem, like a problem with PDH
registers or PDH memory, or a problem with the
concorde or CPU chips.
9051
Troubleshoot the cell to find out if page zero
contents are screwed up or if hardware is just
failed to do the OS write or failed to do the PDC
read. Verify that memory is properly written and
holds contents at the page zero locations. Perhaps
replace the cell board or replace the memory.
Cell Hardware or memory problem that PDC
didn't catch.
9052
Check CPU load ordering
9084
Upgrade PDC if there is a version of PDC that
fixes such a problem.
PDC bug in which PDC is trying to access PDH
memory of a cell not in its partition.
9364
Contact HP Support to confirm the PDH riser
card is functioning properly.
Hardware problem with the PDH riser card.
9365
Troubleshoot the fabric and reseat/replace the
cells or cables or backplane if necessary.
Hardware connecting cells in the partition
experienced a problem such that cells in the
partition together can no longer communicate.
9367
Troubleshoot the cell and/or replace it.
Hardware problem with the CPU, CC, or PDH
flash.
9368
Check for PDC upgrade
PDC bug such that PDC didn't log the relocation
address.
9370
98