HP OmniBook xe3-gc HP OmniBook Notebook PC XE3 Series - Reference Guide - Page 140

S-Registers Ambit

Page 140 highlights

Specifications and Regulatory Information Modem Reference Information Command Function (Ambit) %C2 %C3 \A0 \A1 \A2 \A3 \Bn Enable V.42 bis data compression Enable both V.42 bis and MNP 5 compression Set maximum block size in MNP to 64 Set maximum block size in MNP to 128 Set maximum block size in MNP to 192 Set maximum block size in MNP to 256 Send break of n × 100 ms MNP 10 Commands -K0 -K1 -K2 -SEC=0 -SEC=1, [] Disable MNP 10 extended services Enable MNP 10 extended services Disable MNP 10 extended services detection only Disable MNP 10-EC Enable MNP 10-EC and set transmit level 0 to 30 (0 dBm to -30 dBm) FAX Class 1 +Fclass=1 +FAE=0 +FAE=1 +FRH=n +FRM=n +FRS=n +FTH=n +FTM=n +FTS=n Service class Disable data/fax auto answer Enable data/fax auto answer Receive data with HDLC framing Receive data Receive silence, n×10 ms Transmit data with HDLC framing Transmit data Stop transmission and wait, n×10 ms AT* Commands *B *Cn *NCn Display black-listed number Data calling tone selection Select country parameters: 0=US, 1=Japan, 2=Germany, 3=UK, 4=France, 5=Netherlands, 6=Italy, 7=Australia, 8=Sweden, 9=Denmark, 10=New Zealand, 11=Korea, 12=China, 13=Singapore, 14=Malaysia, 15=South Africa, 16=Poland, 17=Czech Republic, 18=Hungary, 19=Hong Kong, 20=Turkey, 21=Spain. S-Registers (Ambit) Register S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S14 Function (Ambit) Rings to auto-answer Ring counter Escape character Carriage return character Line feed character Backspace character Wait time for dial tone Wait time for carrier Pause time for dial delay modifier Carrier detect response time Carrier loss disconnect time DTMF tone duration Escape prompt delay General bit mapped options status Range/units 0-255/rings 0-255/rings 0-255/ASCII 0-127/ASCII 0-127/ASCII 0-255/ASCII 2-255/s 1-255/s 0-255/s 1-255/.1 s 1-255/.1 s 50-255/.001 s 0-255/.02 s Default 0 0 43 13 10 8 2 50 2 6 14 95 50 138 (8Ah) 140 Reference Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151

Specifications and Regulatory Information
Modem Reference Information
140
Reference Guide
Command
Function (Ambit)
%C2
Enable V.42 bis data compression
%C3
Enable both V.42 bis and MNP 5 compression
\A0
Set maximum block size in MNP to 64
\A1
Set maximum block size in MNP to 128
\A2
Set maximum block size in MNP to 192
\A3
Set maximum block size in MNP to 256
\Bn
Send break of n × 100 ms
MNP 10 Commands
-K0
Disable MNP 10 extended services
-K1
Enable MNP 10 extended services
-K2
Disable MNP 10 extended services detection only
-SEC=0
Disable MNP 10-EC
-SEC=1, [<tx
level>]
Enable MNP 10-EC and set transmit level <tx level> 0 to 30 (0 dBm to -30 dBm)
FAX Class 1
+Fclass=1
Service class
+FAE=0
Disable data/fax auto answer
+FAE=1
Enable data/fax auto answer
+FRH=n
Receive data with HDLC framing
+FRM=n
Receive data
+FRS=n
Receive silence, n×10 ms
+FTH=n
Transmit data with HDLC framing
+FTM=n
Transmit data
+FTS=n
Stop transmission and wait, n×10 ms
AT* Commands
*B
Display black-listed number
*Cn
Data calling tone selection
*NCn
Select country parameters: 0=US, 1=Japan, 2=Germany, 3=UK, 4=France, 5=Netherlands, 6=Italy,
7=Australia, 8=Sweden, 9=Denmark, 10=New Zealand, 11=Korea, 12=China, 13=Singapore, 14=Malaysia,
15=South Africa, 16=Poland, 17=Czech Republic, 18=Hungary, 19=Hong Kong, 20=Turkey, 21=Spain.
S-Registers (Ambit)
Register
Function (Ambit)
Range/units
Default
S0
Rings to auto-answer
0-255/rings
0
S1
Ring counter
0-255/rings
0
S2
Escape character
0-255/ASCII
43
S3
Carriage return character
0-127/ASCII
13
S4
Line feed character
0-127/ASCII
10
S5
Backspace character
0-255/ASCII
8
S6
Wait time for dial tone
2-255/s
2
S7
Wait time for carrier
1-255/s
50
S8
Pause time for dial delay modifier
0-255/s
2
S9
Carrier detect response time
1-255/.1 s
6
S10
Carrier loss disconnect time
1-255/.1 s
14
S11
DTMF tone duration
50-255/.001 s
95
S12
Escape prompt delay
0-255/.02 s
50
S14
General bit mapped options status
138 (8Ah)