HP Scitex FB910 HP Scitex FB910 Printer Series - User Manual - Page 84
inch 900 mm calibration, metal ruler. This is not as precise as the 34-inch 900 mm
View all HP Scitex FB910 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
tendency of the media advance to gradually decrease as the size of the supply roll decreases. You can pause and resume the printing of the stitch pattern. 34-inch (900 mm) calibration - prints a 34-inch (or 900 mm) test pattern so you can verify its length with an accurate metal ruler. Cut the pattern from the media web, then measure and adjust the media advance as needed until the pattern is exactly 34 inches (900 mm) long. 10-inch (250 mm) calibration - prints a 10-inch (or 250 mm) test pattern so you can verify its length with an accurate metal ruler. This is not as precise as the 34-inch (900 mm) calibration, but it uses less media. Measure and adjust the media advance as needed until the pattern is exactly 10 inches (250 mm) long. Fig. 4-5. Measure between the calibration marks 4-22 Manual Calibrations