Honeywell NX4S1 User Guide - Page 82
Table 3-1, Interlock, Function
View all Honeywell NX4S1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
Configuring via WIN-PAK Adding a New NetAXS™ Panel 10.Use the following procedure to reassign the interlocks: a. Display the Readers tab, and then display the first input's configuration window. Select None, and click OK. This dissolves all input interlocks and changes the Shunt Time to 0. This allows the input to be properly redefined for use with NetAXS. b. Repeat the preceding step for each input for each reader on this tab. c. After all interlocks on all inputs for each reader have been dissolved, reassign the interlocks according to Table 3-1 below: Table 3-1: Interlock Reassignments for NetAXS™ Interlock Function 1 Door egress for Door 1 2 Door status switch for Door 1. Shunt time is 15 seconds. 3 Door egress for Door 2. 4 Door status switch for Door 2. Shunt time is 15 seconds. 5 Door egress for Door 3. 6 Door status switch for Door 3. Shunt time is 15 seconds. 7 Door egress for Door 4. 8 Door status switch for Door 4. Shunt time is 15 seconds. 9 Reader 1 tamper/auxiliary. 10 Reader 2 tamper/auxiliary. 11 Reader 3 tamper/auxiliary. 72 www.honeywell.com