6 - Maintenance - Install New Stitch-wire Fit a New Stitch-wire Spool Step 1 2 3 4 Action Open the stitch-wire cabinet. Remove the stitch-wire cap and finished stitch-wire spool. Fit a new stitch-wire spool. Fit the stitch-wire cap. Information 5 Loosen the end of the stitch-wire from the edge of the stitch-wire spool. 6 Use wire-cutters to remove the Remove enough stitch-wire to damaged end of the stitch-wire. leave the end of the stitch-wire clean and straight. 7 Feed the stitch-wire through the stitch-wire guide. 8 Install the stitch-wire. See "Install the Stitch-wire into the Stitch Head" on page 98. Watkiss PowerSquare™224 User Manual 97
6 - Maintenance - Install New Stitch-wire
Watkiss PowerSquare™224 User Manual
97
Fit a New Stitch-wire Spool
Step
Action
Information
1
Open the stitch-wire cabinet.
2
Remove the stitch-wire cap and
finished stitch-wire spool.
3
Fit a new stitch-wire spool.
4
Fit the stitch-wire cap.
5
Loosen the end of the stitch-wire
from the edge of the stitch-wire
spool.
6
Use wire-cutters to remove the
damaged end of the stitch-wire.
Remove enough stitch-wire to
leave the end of the stitch-wire
clean and straight.
7
Feed the stitch-wire through the
stitch-wire guide.
8
Install the stitch-wire.
See “Install the Stitch-wire into the