Konica Minolta C83hc High Chroma AccurioPress C6100/C6085 AccurioPress C3080/C - Page 27
Press [Output], select [Normal] in [Output Method], and press [OK].
View all Konica Minolta C83hc High Chroma manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
3.2 Selecting the Created Reference Image for Automatic Inspection 3 9 Press [New Store] or [Overwrite]. The setting is stored, and the display returns to the [Hold Job] screen. 10 Press [Output], select [Normal] in [Output Method], and press [OK]. The print job starts, and [Auto Inspection] is performed. If an error is detected by the automatic inspection, it is displayed in [IQ Detected Result]. The [Auto Inspection] report can be viewed on this machine or by using Web Utilities of the Auto Inspection Unit UK-301. Tips - Textured paper, blank insertion paper, punched paper, tab paper, and insertion paper are not targeted for automatic inspection. - When using numbered paper, paper with page numbers printed, or the date/time stamp function, set Inspection Excluding Area by reference; you can perform automatic inspection. For details, refer to "6. Automatic Inspection Area" in this manual. Automatic Inspection Operation Manual 3-8