Konica Minolta Kodak Scan Station 710 Administration Guide - Page 118
Replacement procedures, Replacing the separation module and tires, Replacing the separation
View all Konica Minolta Kodak Scan Station 710 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
Replacement procedures Replacing the separation module and tires Kodak Scan Stations use replaceable tires that can feed a wide range of document types, sizes and thicknesses. Tire life and performance will vary based on the customer's document set, the frequency of cleaning the paper path and tires, and following the recommended schedule for changing tires. Nominal tire life is approximately 125,000 pages. Usage figures are not guaranteed. Customer operating environments, document type, the condition of documents being scanned, and not following the recommended cleaning and replacement procedures, can cause the life of the consumables to vary. You should change the tires if you notice an increase in multiple feeds, stoppages, or a decrease in feeder performance that is not resolved by following the cleaning procedures. NOTES: • Before beginning replacement procedures, turn off the Scan Station and disconnect the electrical power. • For certain paper types (such as carbonless paper or newsprint), failure to clean regularly, and/or use of non-recommended cleaning solvents can shorten roller life. 1. Push the separation module up to snap out and lift it out of position. • If you are replacing the separation module, insert the new separation module by aligning the tabs with the slots and snapping it into position. • If you are replacing the tires, continue with Step 2. A-61796 December 2013 10-7