Blurred image, Check media setting, Execute print head cleaning
View all Kyocera TASKalfa Pro 15000c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 120 highlights
Troubleshooting > Troubleshooting When Printing Image Blurred image abc Bad Good 1 Check media setting Media Type and Media Weight (Chapter 15) in Operation Guide In case that no improvement is observed, then go to next step. 2 Execute print head cleaning Discharge amount get small because of high viscosity ink. 1 Load SRA3/Ledger size paper. 2 [Home] key > [...] > [Professional Settings] > [U744 Head Cleaning] > [02 Check] A nozzle check pattern is printed. 3 Align the mark on the chart arrow with the mark on the upper left corner of the platen glass. As shown in the illustration, place the pattern on the glass platen with the printed side down and the edge with the arrows toward the back. NOTE The printed position of the arrows in the nozzle check pattern may be in from the edge, depending on the size of the pattern. Regardless of the position of the arrows, place the pattern in the upper left corner of the glass platen. 4 Select [Start]. After the pattern is scanned, the number of clogged nozzles of each color is displayed. If there is even one clogged nozzle, go to the next step. 5 [Stop] key > select [01 Cleaning]. 4-17