Kyocera TASKalfa Pro 15000c Pro 15000c Advanced Operation Guide - Page 133
Void area at the leading edge, Con print head cleaning operation according to paper, width
View all Kyocera TASKalfa Pro 15000c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 133 highlights
Troubleshooting > Troubleshooting When Printing Image *3 When Void area at the leading edge is observed, configure the settings of U736 as below. In case of temperature is normal or high: U736 >Ink discharge > Job start and Specific Interval > Mode4 (800) In case of temperature is low: U736 >Ink discharge > Job start and Specific Interval > Mode2 (160) *4 If the faint image at the leading edge section occurs right after executing the setting 6, set U734 to [Off], and configure the settings of U736 as below. U736 > Ink discharge > Job start and Specific interval > Mode2 (160) NOTE Settings are set by the environment showed in the chart below. Humi Low Temperature Normal Temperature High Temperature Temp When selecting [04 All], waste paper is printed every job printout. 5 [Start] key > [Stop] key > [Close] The settings are configured and the screen returns to Professional settings menu. 6 In case that no improvement is observed, contact our service representative. Void area at the leading edge HH Bad Good The ink in the nozzles that have not been discharged for a while has become transparent due to material separation caused by evaporation of moisture, etc. 1 Configure print head cleaning operation according to paper width Use this setting when there is any void area at the leading edge of the paper after changing to a print job with a different paper width. 1 [Home] key > [...] > [Professional Settings] > [U730 Set Head Cleaning] > [03 Purge(Width)] 4-30