Lantronix SGX 5150 User Guide - Page 114
Table 9-44, Tunnel Accept Mode Settings, Administration, SGX 5150 IoT Device Gateway User Guide
View all Lantronix SGX 5150 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 114 highlights
9: Administration Tunnel Accept Mode Settings Mode Local Port Protocol TCP Keep Alive Initial Send Flush Serial Table 9-44 Tunnel Accept Mode Settings Description Set the method used to start a tunnel in Accept mode. Choices are: Disable = do not accept an incoming connection. Always = accept an incoming connection (default). Any Character = start waiting for an incoming connection when any character is read on the serial line. Start Character = start waiting for an incoming connection when the start character for the selected tunnel is read on the serial line. Modem Control Asserted = start waiting for an incoming connection as long as the Modem Control pin (DSR) is asserted on the serial line until a connection is made. Modem Emulation = start waiting for an incoming connection when triggered by modem emulation AT commands. Connect mode must also be set to Modem Emulation. Set the port number for use as the network local port. The default local port number for each supported serial line number progresses sequentially in equal value so that Tunnel X: 1000X. For example: Tunnel 1: 10001 Tunnel 2: 10002 Select the protocol type for use with Accept Mode: SSH SSL TCP (default protocol) TCP AES Telnet Enter the time, in milliseconds, the SGX 5150 waits during a silent TCP connection before checking if the currently connected network device is still on the network. If the unit gets no response after 1 attempt, it drops the connection. Enter 0 to disable. Blank the display field to restore the default. Enter the Initial Send data to be sent out the network upon connection establishment before any data from the Line. It may contain one or more Directives of the form %. The Initial Send string can be entered in Text or Binary form. The Binary form allows square braces [ ] to enclose one or more character designations separated by commas. Use straight decimal numbers up to 255 or hexadecimal numbers prefixed with 0x up to 0xFF within the square braces. To specify an open brace in binary mode, use two in a row. Example (in Binary mode): AB[255,0xFF]C[[D]Results in a string containing binary values where the dots appear: AB··C[D] Directives %i local IP address %m MAC address %n network interface name %p local port %s serial number %% % Set whether the serial line data buffer is flushed upon a new network connection. Choices are: Enabled = serial data buffer is flushed on network connection Disabled = serial data buffer is not flushed on network connection (default) SGX 5150 IoT Device Gateway User Guide 114