Lenovo PC 300PL User guide for IBM PC300PL (type 6584, 6594) systems - Page 22

Dimensions, Weight, Environment, Electrical input, Heat output, Airflow, Acoustical noise-emission

Page 22 highlights

Tower model Dimensions Height: 492 mm (19.4 in.) Width: 200 mm (7.9 in.) Depth: 445 mm (17.5 in.) Weight Minimum configuration as shipped: 15 kg (33 lb) Maximum configuration: 17.3 kg (38 lb) Environment Air temperature: - System on: 10° to 32°C (50° to 90°F) - System off: 10° to 43°C (50° to 110°F) Humidity: - System on: 8% to 80% - System off: 8% to 80% Maximum altitude: 2134 m (7000 ft) Electrical input Input voltage: - Low range: - Minimum: 90 V ac - Maximum: 137 V ac - Input frequency range: 57-63 Hz - Voltage switch setting: 115 V - High range: - Minimum: 180 V ac - Maximum: 265 V ac - Input frequency range: 47-53 Hz - Voltage switch setting: 230 V - Input kilovolt-amperes (kVA) (approximately): - Minimum configuration as shipped: 0.08 kVA - Maximum configuration: 0.51 kVA Note: Power consumption and heat output vary depending on the number and type of optional features installed and the power management optional features in use. Heat output Approximate heat output in British thermal units (Btu) per hour: - Minimum configuration: 245 Btu/hr (70 watts) - Maximum configuration: 969 Btu/hr (285 watts) Airflow Approximately 0.56 cubic meters per minute (20 cubic feet per minute) Acoustical noise-emission values Average sound-pressure levels: - At operator position: - Idle: 33 dBA - Operating: 35 dBA - At bystander position-1 meter (3.3 ft): - Idle: 29 dBA - Operating: 32 dBA - Declared (upper limit) sound power levels: - Idle: 4.5 bels - Operating: 4.8 bels Note: These levels were measured in controlled acoustical environments according to procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual sound-pressure levels in your location might exceed the average values stated because of room reflections and other nearby noise sources. The declared sound power levels indicate an upper limit, below which a large number of computers will operate. 8 PC 300PL User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194

Tower model
Dimensions
±
Height: 492 mm (19.4 in.)
±
Width:
200 mm (7.9 in.)
±
Depth:
445 mm (17.5 in.)
Weight
±
Minimum configuration as shipped:
15
kg (33 lb)
±
Maximum configuration:
17.3 kg (38 lb)
Environment
±
Air temperature:
System on:
10° to 32°C (50° to 90°F)
System off:
10° to 43°C (50° to 110°F)
±
Humidity:
System on:
8% to 80%
System off:
8% to 80%
±
Maximum altitude:
2134 m (7000 ft)
Electrical input
±
Input voltage:
Low range:
-
Minimum:
90 V ac
-
Maximum:
137 V ac
-
Input frequency range:
57-63 Hz
-
Voltage switch setting:
115 V
High range:
-
Minimum:
180 V ac
-
Maximum:
265 V ac
-
Input frequency range:
47-53 Hz
-
Voltage switch setting:
230 V
Input kilovolt-amperes (kVA)
(approximately):
-
Minimum configuration as
shipped: 0.08 kVA
-
Maximum configuration:
0.51
kVA
Note:
Power consumption and heat
output vary depending on the
number and type of optional
features installed and the power
management optional features in
use.
Heat output
±
Approximate heat output in British
thermal units (Btu) per hour:
Minimum configuration:
245 Btu/hr
(70 watts)
Maximum configuration:
969 Btu/hr
(285 watts)
Airflow
±
Approximately 0.56 cubic meters per
minute (20
cubic feet per minute)
Acoustical noise-emission values
±
Average sound-pressure levels:
At operator position:
-
Idle:
33 dBA
-
Operating:
35 dBA
At bystander position–1 meter (3.3
ft):
-
Idle:
29 dBA
-
Operating:
32 dBA
Declared (upper limit) sound power
levels:
-
Idle:
4.5 bels
-
Operating:
4.8 bels
Note:
These levels were measured in
controlled acoustical environments
according to procedures specified by the
American National Standards Institute
(ANSI) S12.10 and ISO 7779 and are
reported in accordance with ISO 9296.
Actual sound-pressure levels in your