Samsung SRP-275CEPG Operation Manual - Page 60

GS C pL pH m fn b d1 d2 d3 <Function 6&gt

Page 60 highlights

CHAPTER 5 CONTROL COMMANDS LIST - See [Notes for transmission process] for description of transmission process. - See [Notes for ESC/POS Handshaking Protocol] for description of ESC/POS Handshaking Protocol. GS ( C pL pH m fn b d1 d2 d3 [Format] ASCII GS ( C pL pH m fn b d1 d2 d3 Hex 1D 28 43 06 00 00 fn 00 43 4C 52 Decimal 29 40 67 6 0 0 fn 0 67 76 82 [Range] (pL + pH x 256) = 6 ( pL = 6, pH = 0) m = 0 fn = 6, 54 b = 0 d1 = 67 d2 = 76 d3 = 82 [Description] The printer deletes all records stored in the NV user memory. [Notes] - All area is changed to unused area. This command is effective only at the beginning of the line. This command cannot include macros; therefore, do not use this command when defining macros. 5-50 GS ( D [Name] Enable/disable real-time command [Format] ASCII GS ( D pL pH m [a1 b1]...[ak bk] Hex 1D 28 44 pL pH 14 [a1 b1]...[ak bk] Decimal 29 40 68 pL pH 20 [a1 b1]...[ak bk] [Range] (pL + pH x 256) = 3, 5 ( pL = 3, 5, pH = 0) m = 20 a = 1 b = 0, 1, 48, 49 [Default] a = 1/ b = 1 (DLE DC4 fn m t ( n = 1): enable) [Description] Specifies enable or disable of a real-time command. - pL, pH sets the number of parameters after pH (m and [a1 b1]...[ak bk]) to (pL + pH x 256) bytes. - a specifies the type of real-time command. - b specifies enable/disable of real-time command processing. a b Real-time command type Disable DLE DC4 n m t ( n = 1): output a specified pulse in real-time 1 0, 48 (It does not process) Enable DLE DC4 n m t ( n = 1): output a specified pulse in real-time 1, 49 (It does process) DLE DC4 n m t (n=1): output a specified pulse in real-time. [Notes] - The printer processes each real-time command that is enabled upon receiving it. - A real-time command specified as disabled is not processed. - The setting of this command is effective until ESC @ is executed, the printer is reset, or the power is turned off. - If you transmit a command for a bit image or defined data that contains the sequence DLE DC4, be sure to disable real-time command processing before transmitting the bit image or defined data command. Then the printer will process the sequence DLE DC4 as image data. 5-51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

5-51
GS ( D
[Name]
Enable/disable real-time command
[Format]
ASCII
GS
(
D
pL
pH
m
[a1 b1]...[ak bk]
Hex
1D
28
44
pL
pH
14
[a1 b1]...[ak bk]
Decimal 29
40
68
pL
pH
20
[a1 b1]...[ak bk]
[Range]
(pL + pH x 256) = 3, 5 ( pL = 3, 5, pH = 0)
m = 20
a = 1
b = 0, 1, 48, 49
[Default]
a = 1/ b = 1 (DLE DC4 fn m t ( n = 1): enable)
[Description]
Specifies enable or disable of a real-time command.
-
pL, pH sets the number of parameters after pH (m and [a1 b1]...[ak bk])
to (pL + pH x 256) bytes.
-
a specifies the type of real-time command.
-
b specifies enable/disable of real-time command processing.
[Notes]
-
The printer processes each real-time command that is enabled upon
receiving it.
-
A real-time command specified as disabled is not processed.
-
The setting of this command is effective until ESC @ is executed,
the printer is reset, or the power is turned off.
-
If you transmit a command for a bit image or defined data that contains the
sequence DLE DC4, be sure to disable real-time command processing
before transmitting the bit image or defined data command.
Then the printer will process the sequence DLE DC4 as image data.
5-50
GS ( C pL pH m fn b d1 d2 d3 <Function 6>
[Format]
ASCII
GS
(
C
pL
pH
m
fn
b
d1
d2
d3
Hex
1D
28
43
06
00
00
fn
00
43
4C
52
Decimal
29
40
67
6
0
0
fn
0
67
76
82
[Range]
(pL + pH x 256) = 6 ( pL = 6, pH = 0)
m = 0
fn = 6, 54
b = 0
d1 = 67
d2 = 76
d3 = 82
[Description]
The printer deletes all records stored in the NV user memory.
-
All area is changed to unused area.
[Notes]
This command is effective only at the beginning of the line.
This command cannot include macros; therefore, do not use this command
when defining macros.
a
b
Real-time command type
Disable DLE DC4 n m t ( n = 1): output a specified pulse in real-time
(It does not process)
Enable DLE DC4 n m t ( n = 1): output a specified pulse in real-time
(It does process)
DLE DC4 n m t (n=1): output a specified pulse in real-time.
CONTROL COMMANDS LIST
CHAPTER 5
1
0, 48
1, 49
-
See [Notes for transmission process] for description of transmission
process.
-
See [Notes for ESC/POS Handshaking Protocol] for description of