Sony SRR4 Product Manual (SRMASTER: SRR4 Operation Manual) - Page 41

R RUN [Rec Run], DF [Drop Frm], TCG [TCG Source], 24H [24H], AUTO [Auto], 2F [+2F Delay], Setting Item

Page 41 highlights

Setting Item Settings RUN MODE Selects the run mode of the internal time code generator. F RUN [Free Run]: Advances the time code while the power is on. R RUN [Rec Run]: Advances the time code only during recording. TCG SET Time code generator settings related to the main time code DF/NDF Sets the frame count mode. (Valid only when the frame DF [Drop Frm]: Drop frame mode frequency of this system is NDF [Non Drop Frm]: Non-drop frame mode 29.97 Hz.) Note UBG SOURCE 12H/24H This settings is valid only when TCG MODE is set to "PRST." Selects the source time code of user bits. TCG [TCG Source]: Same source time code as that of the time code generator INT [Internal]: Time code generated by the time code generator. Arbitrary user bits can be set regardless of the setting of TCG (see page 34). Selects the TIMER display mode. 12H [+/-12H]: 12-hour display mode 24H [24H]: 24-hour display mode Note OTHERS TC OUT Other settings related to the main time code TC Delay When +/-12H display is selected, the tens digit of the hours value is dropped for values less than 10. Selects the time code to output from the TC OUT connector. AUTO [Auto]: During playback, the time code read by the internal time code reader. During recording or when in E-E mode, the time code generated by the time code generator. TCG [TCG]: The time code generated by the time code generator. THRU [Through]: Outputs the time code input to the TC IN connector as is. Sets the phase difference between the LTC input from the TC IN connector and the time code generator. 0 [NO Delay]: Same timing +1F [+1F Delay]: The generator is delayed by one frame. +2F [+2F Delay]: The generator is delayed by two frames. +3F [+3F Delay]: The generator is delayed by three frames. +4F [+4F Delay]: The generator is delayed by four frames. +5F [+5F Delay]: The generator is delayed by five frames. Chapter 5 Menu Details TC Setup Menu 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61

TC Setup Menu
41
Chapter 5
Menu Details
RUN MODE
Selects the run mode of the internal time code generator.
F RUN [Free Run]: Advances the time code while the
power is on.
R RUN [Rec Run]:
Advances the time code only during
recording.
TCG SET
Time code generator
settings related to the
main time code
DF/NDF
(Valid only when the frame
frequency of this system is
29.97 Hz.)
Sets the frame count mode.
DF [Drop Frm]:
Drop frame mode
NDF [Non Drop Frm]: Non-drop frame mode
Note
This settings is valid only when TCG MODE is set to
“PRST.”
UBG SOURCE
Selects the source time code of user bits.
TCG [TCG Source]:
Same source time code as that of
the time code generator
INT [Internal]: Time code generated by the time code
generator. Arbitrary user bits can be set regardless of
the setting of TCG
(see page 34)
.
12H/24H
Selects the TIMER display mode.
12H [+/–12H]: 12-hour display mode
24H [24H]:
24-hour display mode
Note
When +/–12H display is selected, the tens digit of the
hours value is dropped for values less than 10.
OTHERS
Other settings related
to the main time code
TC OUT
Selects the time code to output from the TC OUT
connector.
AUTO [Auto]:
During playback, the time code read by
the internal time code reader. During recording or when
in E-E mode, the time code generated by the time code
generator.
TCG [TCG]: The time code generated by the time code
generator.
THRU [Through]: Outputs the time code input to the TC
IN connector as is.
TC Delay
Sets the phase difference between the LTC input from the
TC IN connector and the time code generator.
0 [NO Delay]: Same timing
+1F [+1F Delay]: The generator is delayed by one frame.
+2F [+2F Delay]:
The generator is delayed by two
frames.
+3F [+3F Delay]: The generator is delayed by three
frames.
+4F [+4F Delay]: The generator is delayed by four
frames.
+5F [+5F Delay]: The generator is delayed by five frames.
Setting Item
Settings