TASCAM DA-6400 TELNET protocol specifications - Page 21
Error Sense Request, Caution Sense Request, Illegal Status, Change Status
![]() |
View all TASCAM DA-6400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
TASCAM DA-6400/DA-6400dp TELNET protocol specifications ERROR SENSE REQUEST This command is returned when the error status changes. Send ERROR SENSE [78] from the controlling device to check the error details. Command F0 Machine ID 0 Data none Request/Preset none CAUTION SENSE REQUEST This command is returned when the caution status changes. Send CAUTION SENSE [79] from the controlling device to check the caution details. Command F1 Machine ID 0 Data none Request/Preset none ILLEGAL STATUS This command is returned when an invalid command or data is sent to the controlled device. If this command is returned from the controlled device, have the controlling device send a command or data that complies with the specifications. Command F2 Machine ID 0 Data none Request/Preset none CHANGE STATUS This command notifies that the controlled device operation or mode has changed. Command F6 Machine ID 0 Data 2 bytes Data 1 Data 2 Meaning Notes 0 0 Changed Mechanical Status Operation status has changed 0 3 Changed Track Take number has changed Request/Preset none 21 TEAC Corporation