TASCAM DA-6400 TELNET protocol specifications - Page 34

Tc Generator Mode Select, Tc Frame Type Select

Page 34 highlights

TASCAM DA-6400/DA-6400dp TELNET protocol specifications TC GENERATOR MODE SELECT This sets the TC GENERATOR mode of the controlled device. A return command is only sent when Sense [FF] is specified. Command 7F Category Code 06 Sub Command 20 Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 0 0 FREE RUN FREE RUN timecode generator mode 0 1 FREE ONCE FREE ONCE timecode generator mode 0 2 TIME OF DAY TIME OF DAY timecode generator mode 0 3 JAM SYNC JAM SYNC timecode generator mode 0 4 REGEN REGEN timecode generator mode 0 5 REC RUN REC RUN timecode generator mode 0 6 TC SYNC REC TC SYNC REC timecode generator mode F F Sense This requests that the preset contents be returned. ・ If the unit receives any Data other than the above, it will send ILLEGAL [F2]. Return TC GENERATOR MODE RETURN [FF06A0] TC FRAME TYPE SELECT This sets the TC FRAME TYPE of the controlled device. A return command is only sent when Sense [FF] is specified for Data 5 and Data 6. Command 7F Category Code 06 Sub Command 21 Machine ID 0 Parameter 2 or 4 bytes Data 5 Data 6 Data 7 Data 8 Meaning Notes 2 3 23.976F 23.976F timecode frame type 2 4 24F 24F timecode frame type 2 5 25F 25F timecode frame type 2 9 D F 29.97DF 29.97DF timecode frame type 2 9 29.97NDF 29.97NDF timecode frame type 3 0 D F 30DF 30DF timecode frame type 3 0 30NDF 30NDF timecode frame type F F Sense This requests that the preset contents be returned. ・ If the unit receives any Data other than the above, it will send ILLEGAL [F2]. Return TC FRAME TYPE RETURN [FF06A1] 34 TEAC Corporation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

TASCAM DA-6400/DA-6400dp TELNET protocol specifications
34
TEAC Corporation
TC GENERATOR MODE SELECT
This sets the TC GENERATOR mode of the controlled device.
A return command is only sent when Sense [FF] is specified.
Command
7F
Category Code
06
Sub Command
20
Machine ID
0
Parameter
2 bytes
Data 5
Data 6
Meaning
Notes
0
0
FREE RUN
FREE RUN timecode generator mode
0
1
FREE ONCE
FREE ONCE timecode generator mode
0
2
TIME OF DAY
TIME OF DAY timecode generator mode
0
3
JAM SYNC
JAM SYNC timecode generator mode
0
4
REGEN
REGEN timecode generator mode
0
5
REC RUN
REC RUN timecode generator mode
0
6
TC SYNC REC
TC SYNC REC timecode generator mode
F
F
Sense
This requests that the preset contents be returned.
If the unit receives any Data other than the above, it will send ILLEGAL [F2].
Return
TC GENERATOR MODE RETURN [FF06A0]
TC FRAME TYPE SELECT
This sets the TC FRAME TYPE of the controlled device.
A return command is only sent when Sense [FF] is specified for Data 5 and Data 6.
Command
7F
Category Code
06
Sub Command
21
Machine ID
0
Parameter
2 or 4 bytes
Data 5
Data 6
Data 7
Data 8
Meaning
Notes
2
3
23.976F
23.976F timecode frame type
2
4
24F
24F timecode frame type
2
5
25F
25F timecode frame type
2
9
D
F
29.97DF
29.97DF timecode frame type
2
9
29.97NDF
29.97NDF timecode frame type
3
0
D
F
30DF
30DF timecode frame type
3
0
30NDF
30NDF timecode frame type
F
F
Sense
This requests that the preset contents be returned.
If the unit receives any Data other than the above, it will send ILLEGAL [F2].
Return
TC FRAME TYPE RETURN [FF06A1]