TASCAM DA-6400 TELNET protocol specifications - Page 66
Meter Peak Hold Time Return
View all TASCAM DA-6400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
TASCAM DA-6400/DA-6400dp TELNET protocol specifications METER PEAK HOLD TIME RETURN This is a return command in response to a "METER PEAK HOLD TIME PRESET [7F1321]" command. This returns the meter peak hold setting. Command FF Category Code 13 Sub Command A1 Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 0 0 Hold Time 0s No peak hold 0 1 Hold Time 1s Hold for 1 seconds 0 2 Hold Time 2s Hold for 2 seconds 0 3 Hold Time 3s Hold for 3 seconds 0 4 Hold Time 4s Hold for 4 seconds 0 5 Hold Time 5s Hold for 5 seconds 0 6 Hold Time 6s Hold for 6 seconds 0 7 Hold Time 7s Hold for 7 seconds 0 8 Hold Time 8s Hold for 8 seconds 0 9 Hold Time 9s Hold for 9 seconds 1 0 Hold Time 10s Hold for 10 seconds F E Hold Time Inf. Hold permanently Request/Preset METER PEAK HOLD TIME SELECT [7F1321] 66 TEAC Corporation