TASCAM DA-6400 TELNET protocol specifications - Page 28

Category Code

Page 28 highlights

TASCAM DA-6400/DA-6400dp TELNET protocol specifications MARK TIME PRESET Specify a mark number and change its time. The mark number is the number counted from the beginning in chronological order. Command 7F Category Code 03 Sub Command 24 Machine ID 0 Parameter 12 bytes Meaning Notes Data 5 Mark number tens digit Data 6 Mark number ones digit Mark number Data 7 Mark number thousands digit Example: "9800" is mark 98 Data 8 Mark number hundreds digit Data 9 Hour tens digit Data 10 Hour ones digit Data 11 Minute tens digit Data 12 Minute ones digit Data 13 Second tens digit Data 14 Second ones digit Data 15 Frame tens digit Data 16 Frame ones digit ・ If a number is specified for a mark that does not exist in the current take, the unit will return ILLEGAL [F2]. ・ If a time longer than the current take is specified, the unit will return ILLEGAL [F2]. Return none 28 TEAC Corporation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

TASCAM DA-6400/DA-6400dp TELNET protocol specifications
28
TEAC Corporation
MARK TIME PRESET
Specify a mark number and change its time.
The mark number is the number counted from the beginning in chronological order.
Command
7F
Category Code
03
Sub Command
24
Machine ID
0
Parameter
12 bytes
Meaning
Notes
Data 5
Mark number tens digit
Mark number
Example: "9800" is mark 98
Data 6
Mark number ones digit
Data 7
Mark number thousands digit
Data 8
Mark number hundreds digit
Data 9
Hour tens digit
Data 10
Hour ones digit
Data 11
Minute tens digit
Data 12
Minute ones digit
Data 13
Second tens digit
Data 14
Second ones digit
Data 15
Frame tens digit
Data 16
Frame ones digit
If a number is specified for a mark that does not exist in the current take, the unit will return ILLEGAL [F2].
If a time longer than the current take is specified, the unit will return ILLEGAL [F2].
Return
none