TASCAM DA-6400 TELNET protocol specifications - Page 57
This returns the WORD/VIDEO SETUP setting.
![]() |
View all TASCAM DA-6400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
TASCAM DA-6400/DA-6400dp TELNET protocol specifications CLOCK MASTER RETURN This is a return command in response to a "CLOCK MASTER SELECT [7F0640]" command. This returns the master clock setting. Command FF Category Code 06 Sub Command C0 Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 0 0 Internal Internal master clock 0 1 WORD Word master clock 0 2 VIDEO Video master clock 0 3 SLOT1 Master clock slot 1 0 4 SLOT2 Master clock slot 2 Request/Preset CLOCK MASTER SELECT [7F0640] WORD THRU RETURN This is a return command in response to a "WORD THRU SELECT [7F0648]" command. This returns the WORD/VIDEO SETUP setting. Command FF Category Code 06 Sub Command C8 Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 0 0 WORD OUT/TERM ON Word out/termination on 0 1 WORD OUT/TERM OFF Word out/termination off 1 1 WORD THRU/TERM OFF Word thru/termination off Request/Preset WORD THRU SELECT [7F0648] RECORD FUNCTION RETURN This is a return command in response to a "RECORD FUNCTION SELECT [7F0800]" command. This returns the record function settings for all channels. Command FF Category Code 08 Sub Command 80 Machine ID 0 Parameter 68 bytes Meaning Notes Data 5 Data 6 Data 7 Always "0100" Start channel number From channel 1 Data 8 Data 9 Channel 1 record function setting ・ ・ 0 = off/1 = on ・ Data72 Channel 64 record function setting Request/Preset RECORD FUNCTION SELECT [7F0800] 57 TEAC Corporation
![](/manual_guide/products/tascam-da6400-telnet-protocol-specifications-15cb01f/57.png)