TASCAM DA-6400 TELNET protocol specifications - Page 57

This returns the WORD/VIDEO SETUP setting.

Page 57 highlights

TASCAM DA-6400/DA-6400dp TELNET protocol specifications CLOCK MASTER RETURN This is a return command in response to a "CLOCK MASTER SELECT [7F0640]" command. This returns the master clock setting. Command FF Category Code 06 Sub Command C0 Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 0 0 Internal Internal master clock 0 1 WORD Word master clock 0 2 VIDEO Video master clock 0 3 SLOT1 Master clock slot 1 0 4 SLOT2 Master clock slot 2 Request/Preset CLOCK MASTER SELECT [7F0640] WORD THRU RETURN This is a return command in response to a "WORD THRU SELECT [7F0648]" command. This returns the WORD/VIDEO SETUP setting. Command FF Category Code 06 Sub Command C8 Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 0 0 WORD OUT/TERM ON Word out/termination on 0 1 WORD OUT/TERM OFF Word out/termination off 1 1 WORD THRU/TERM OFF Word thru/termination off Request/Preset WORD THRU SELECT [7F0648] RECORD FUNCTION RETURN This is a return command in response to a "RECORD FUNCTION SELECT [7F0800]" command. This returns the record function settings for all channels. Command FF Category Code 08 Sub Command 80 Machine ID 0 Parameter 68 bytes Meaning Notes Data 5 Data 6 Data 7 Always "0100" Start channel number From channel 1 Data 8 Data 9 Channel 1 record function setting ・ ・ 0 = off/1 = on ・ Data72 Channel 64 record function setting Request/Preset RECORD FUNCTION SELECT [7F0800] 57 TEAC Corporation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

TASCAM DA-6400/DA-6400dp TELNET protocol specifications
57
TEAC Corporation
CLOCK MASTER RETURN
This is a return command in response to a "CLOCK MASTER SELECT [7F0640]" command.
This returns the master clock setting.
Command
FF
Category Code
06
Sub Command
C0
Machine ID
0
Parameter
2 bytes
Data 5
Data 6
Meaning
Notes
0
0
Internal
Internal master clock
0
1
WORD
Word master clock
0
2
VIDEO
Video master clock
0
3
SLOT1
Master clock slot 1
0
4
SLOT2
Master clock slot 2
Request/Preset
CLOCK MASTER SELECT [7F0640]
WORD THRU RETURN
This is a return command in response to a "WORD THRU SELECT [7F0648]" command.
This returns the WORD/VIDEO SETUP setting.
Command
FF
Category Code
06
Sub Command
C8
Machine ID
0
Parameter
2 bytes
Data 5
Data 6
Meaning
Notes
0
0
WORD OUT/TERM ON
Word out/termination on
0
1
WORD OUT/TERM OFF
Word out/termination off
1
1
WORD THRU/TERM OFF
Word thru/termination off
Request/Preset
WORD THRU SELECT [7F0648]
RECORD FUNCTION RETURN
This is a return command in response to a "RECORD FUNCTION SELECT [7F0800]" command.
This returns the record function settings for all channels.
Command
FF
Category Code
08
Sub Command
80
Machine ID
0
Parameter
68 bytes
Meaning
Notes
Data 5
Always "0100"
Start channel number
From channel 1
Data 6
Data 7
Data 8
Data 9
Channel 1 record function setting
0 = off/1 = on
Data72
Channel 64 record function setting
Request/Preset
RECORD FUNCTION SELECT [7F0800]