TASCAM DA-6400 TELNET protocol specifications - Page 40

Time Interval Marker Select, Sync Unlock Marker Select, Rec Fs Select

Page 40 highlights

TASCAM DA-6400/DA-6400dp TELNET protocol specifications TIME INTERVAL MARKER SELECT This sets the TIME INTERVAL MARKER of the controlled device. A return command is only sent when Sense [FF] is specified. Command 7F Category Code 08 Sub Command 42 Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 0 0 Marker Off TIME INTERVAL MARKER OFF 0 1 Marker On TIME INTERVAL MARKER ON F F Sense This requests that the preset contents be returned. ・ If the unit receives any Data other than the above, it will send ILLEGAL [F2]. Return TIME INTERVAL MARKER RETURN [FF08C2] SYNC UNLOCK MARKER SELECT This sets the SYNC UNLOCK MARKER of the controlled device. A return command is only sent when Sense [FF] is specified. Command 7F Category Code 08 Sub Command 43 Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 0 0 Marker Off SYNC UNLOCK MARKER OFF 0 1 Marker On SYNC UNLOCK MARKER ON F F Sense This requests that the preset contents be returned. ・ If the unit receives any Data other than the above, it will send ILLEGAL [F2]. Return SYNC UNLOCK MARKER RETURN [FF08C3] REC FS SELECT This sets the REC FS used by the controlled device. A return command is only sent when Sense [FF] is specified for Data 5 and Data 6. Command 7F Category Code 08 Sub Command 50 Machine ID 0 Parameter 2 or 6 bytes Data 5 Data 6 Data 7 Data 8 Data 9 Data 10 Meaning Notes 4 4 0 0 0 0 44.1 kHz 4 8 0 0 0 0 48 kHz 8 8 0 0 0 0 88.2 kHz 9 6 0 0 0 0 96 kHz F F Sense This requests that the preset contents be returned. ・ If the unit receives any Data other than the above, it will send ILLEGAL [F2]. Return REC FS RETURN [FF08D0] 40 TEAC Corporation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

TASCAM DA-6400/DA-6400dp TELNET protocol specifications
40
TEAC Corporation
TIME INTERVAL MARKER SELECT
This sets the TIME INTERVAL MARKER of the controlled device.
A return command is only sent when Sense [FF] is specified.
Command
7F
Category Code
08
Sub Command
42
Machine ID
0
Parameter
2 bytes
Data 5
Data 6
Meaning
Notes
0
0
Marker Off
TIME INTERVAL MARKER OFF
0
1
Marker On
TIME INTERVAL MARKER ON
F
F
Sense
This requests that the preset contents be returned.
If the unit receives any Data other than the above, it will send ILLEGAL [F2].
Return
TIME INTERVAL MARKER RETURN [FF08C2]
SYNC UNLOCK MARKER SELECT
This sets the SYNC UNLOCK MARKER of the controlled device.
A return command is only sent when Sense [FF] is specified.
Command
7F
Category Code
08
Sub Command
43
Machine ID
0
Parameter
2 bytes
Data 5
Data 6
Meaning
Notes
0
0
Marker Off
SYNC UNLOCK MARKER OFF
0
1
Marker On
SYNC UNLOCK MARKER ON
F
F
Sense
This requests that the preset contents be returned.
If the unit receives any Data other than the above, it will send ILLEGAL [F2].
Return
SYNC UNLOCK MARKER RETURN [FF08C3]
REC FS SELECT
This sets the REC FS used by the controlled device.
A return command is only sent when Sense [FF] is specified for Data 5 and Data 6.
Command
7F
Category Code
08
Sub Command
50
Machine ID
0
Parameter
2 or 6 bytes
Data 5
Data 6
Data 7
Data 8
Data 9
Data 10
Meaning
Notes
4
4
0
0
0
0
44.1 kHz
4
8
0
0
0
0
48 kHz
8
8
0
0
0
0
88.2 kHz
9
6
0
0
0
0
96 kHz
F
F
Sense
This requests that the
preset
contents
be
returned.
If the unit receives any Data other than the above, it will send ILLEGAL [F2].
Return
REC FS RETURN [FF08D0]