TASCAM DA-6400 TELNET protocol specifications - Page 33
Tc Start Time Preset, Tc User Bits Preset, Tc Restart
View all TASCAM DA-6400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
TASCAM DA-6400/DA-6400dp TELNET protocol specifications TC START TIME PRESET Change the TC START TIME on the controlled device. A return command is only sent when Sense [FF] is specified for Data 5 and Data 6. Command 7F Category Code 06 Sub Command 10 Machine ID 0 Parameter 8 bytes Meaning Notes Data 5 Hour tens digit Data 6 Hour ones digit Data 7 Minute tens digit Data 8 Minute ones digit 0-9 Data 9 Second tens digit Data 10 Second ones digit Data 11 Frame tens digit Data 12 Frame ones digit ・ If the unit receives any Data set outside the range, it will send ILLEGAL [F2]. Return TC START TIME RETURN [FF0690] TC USER BITS PRESET Change the TC USER BITS on the controlled device. A return command is only sent when Sense [FF] is specified for Data 5 and Data 6. Command 7F Category Code 06 Sub Command 11 Machine ID 0 Parameter 8 bytes Meaning Notes Data 5 Hour tens digit Data 6 Hour ones digit Data 7 Minute tens digit Data 8 Data 9 Minute ones digit Second tens digit 0-9/A-F Data 10 Second ones digit Data 11 Frame tens digit Data 12 Frame ones digit ・ If the unit receives any Data set outside the range, it will send ILLEGAL [F2]. Return TC USER BITS RETURN [FF0691] TC RESTART This restarts the controlled device TC GENERATOR from the START TIME. If the generator mode is anything other than FREE RUN or REC RUN, this command will be ignored. Command 7F Category Code 06 Sub Command 12 Machine ID 0 Parameter none Return none 33 TEAC Corporation