TASCAM DA-6400 TELNET protocol specifications - Page 47
Digital Refrence Level Preset
![]() |
View all TASCAM DA-6400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
TASCAM DA-6400/DA-6400dp TELNET protocol specifications DIGITAL REFRENCE LEVEL PRESET This sets the DIGITAL REFERENCE LEVEL used by the controlled device. A return command is only sent when Sense [FF] is specified. Command 7F Category Code 14 Sub Command 20 Machine ID 0 Parameter 2 bytes Data 5 Data 6 Meaning Notes 0 9 Reference Level - 9dB -9dB digital reference level 1 4 Reference Level -14dB -14dB digital reference level 1 6 Reference Level -16dB -16dB digital reference level 1 8 Reference Level -18dB -18dB digital reference level 2 0 Reference Level -20dB -20dB digital reference level F F Sense This requests that the preset contents be returned. ・ If the unit receives any Data other than the above, it will send ILLEGAL [F2]. Return DIGITAL REFERENCE LEVEL RETURN [FF14A0] 47 TEAC Corporation