TASCAM DA-6400 TELNET protocol specifications - Page 23
Sub Command
View all TASCAM DA-6400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
TASCAM DA-6400/DA-6400dp TELNET protocol specifications VENDER COMMAND RETURN This is a return command in response to COMMAND [7F]. For details, see "Vender command details" below. Vender command details DA-6400/DA-6400dp vender commands are structured with the following format. Byte 1 2 3 4 5 6 7 8 ... ID Command Data 1 Data 2 Data 3 Data 4 Data 5 ... '0' '7F' or 'FF' Category Code Sub Command Parameter ... n-1 n LF CR LF CR Category Code: Sub Command: Parameter Category code (2-byte ASCII) to distinguish vender commands by function Unique sub-command code (2-byte ASCII) within a category Parameter added to a command code (ASCII, length depends on sub-command) The list of category codes is as follows. Category Code Category 02 Project 03 Mark 06 Timecode 08 Recording 10 Media formatting 11 External control 12 Inputs and outputs 13 Meter 14 System 42 Take editing Explanation Function related to projects Function related to marks Setting related to timecode Setting related to recording Operation related to media Setting related to external control Setting related to inputs and outputs Setting related to meters Setting related to the system Editing by individual take 23 TEAC Corporation